INSTALLING OPTIONAL BRICK LINER EHL-24-1.
1. Remove screen assembly from fireplace.
2. Remove logs from burner assembly.
3. Insert rear brick liner and (2) side brick liners onto bottom
of the inner casing. Align grout lines on rear brick liner with
grout lines on side brick liners. You must insert rear brick
liner before inserting the (2) side brick liners.
4. Loosen top and bottom 10 x 1/2" screws from each side of
firebox.
5. Place the (2) liner mounting brackets over the front edges
of the (2) side brick liners. Attach liner mounting brackets
to outer casing with (4) four 10 x 1/2" screws from Step 4.
6. Replace logs into burner assembly. Refer to "Log Placement,"
Page 12.
7. Attach screen assembly to fireplace.
8. Installation of optional brick liner is completed.
PARTS LIST FOR EHL-24-1, BRICK LINER KIT
Part
Number Description
11504 Liner Mounting Bracket - Front, 2 Required
R-5769 Brick Liner - Rear
R-5770 Brick Liner - Side Left
R-5771 Brick Liner - Side Right
EHL-24-1 for Unvented Gas Fireplace
Model