Page 1323099-1-0707
Before you begin: if you are installing logs onto the VFD(R,T,M)18
or VFD(R,T,M)24 models, this burner assembly is supplied with a
set of five ceramic fiber logs. Do not handle these logs with your
bare hands! Always wear gloves to prevent skin irritation from
ceramic fibers. After handling logs, wash your hands gently with
soap and water to remove any traces of fibers.
The positioning of the logs is critical to the safe and clean operation
of this burner assembly. Sooting and other problems may result
if the logs are not properly and firmly positioned on the burner
assembly. Refer to Figure 12 and Figure 13 and corresponding
WARNING: when completing following log placement instruc-
tions.
1. Place front logs (#1 and #2) between front grate flange and
main burner. Align notches on front logs with locator tabs in
base.
2. Place middle log (#3) between front and rear loop of burner.
Note: Do not place log on top of pilot assembly.
3. Place rear log (#4) on rear log shelf. Bottom flange of log must
be placed between the log shelf and burner tube.
4. This step is optional for VFDR18LB10 log sets. Place front
twig (#5) onto (#1) log and flat area on (#3) log. The bottom
of the front twig is to be placed behind the grate tang that is
second from the left.
EMBER MATERIAL PLACEMENT ON BURNER
5. After all logs are positioned properly, apply Rockwool ember
material to the front burner port area. To apply, carefully
separate the ember material into small amounts no larger than
"dime size" pieces. Fluffed up pieces one layer thick on top
of the burner generally works best, and will provide the best
ember glow. Do not place ember material more than one layer
thick. No more than (2) two small packets of ember material
(part no. 15998) evenly placed on the burner, is recommended
on VFDR18 and VFDR24 models. Using additional ember
material will decrease the amount of ember glow effect. Extra
ember material should be saved for future ember applications
as necessary. See Figure 13.
Figure 12
WARNING: Failure to position the parts in accordance with
this diagram or failure to use only parts specifically approved
with this appliance may result in property damage or personal
injury.
Attention: Do not use Figure 12 or Figure 13 to order logs. Refer
to Parts Lists and Parts Views to order logs and/or ember material
for your appropriate model.
Figure 13
1
4
5
3
2
VFD(R,T,M)(18,24) & VFDR18LB10 LOG PLACEMENT (5 LOG SET)
Description Part #
VFD(R,T,M)18 Embers
15998
VFD(R,T,M)24 Embers
15998
VFD(R,T,M)30 Embers
15999
Platinum Bright Embers PE20-1
Note: A single layer of embers is to be used when applying
Platinum Bright Embers (alone or in combination with stndard
embers) to the burner.