Empire Comfort Systems DVD32FP3-1, DVD36FP3-1, DVD42FP3-1, DVD48FP3-1,DVD32FP5-2, DVD36FP5-2, DVD42FP5-2, DVD48FP5-2 Indoor Fireplace User Manual


 
23552-1-0607 Page 7
Figure 1
Dim DVD32 DVD36 DVD42 DVD48
A 34"
864mm
37"
940 mm
43"
1092 mm
49"
1245 mm
B 31"
787 mm
34"
864 mm
40"
1016 mm
46"
1168 mm
C 23 1/16"
585 mm
23 1/16"
585 mm
25 1/16"
636 mm
25 1/16"
636 mm
D 35 5/8"
905 mm
35 5/8"
905 mm
37 5/8"
956 mm
37 5/8"
956 mm
E 32 3/4"
832 mm
32 3/4"
832mm
34 3/4"
883 mm
34 3/4"
883 mm
F 16 3/8"
416 mm
16 3/8"
416 mm
16 3/8
416 mm
16 3/8"
416 mm
G 24 1/2"
622 mm
24 1/2"
622 mm
26 1/2"
673 mm
26 1/2"
673 mm
H 7 1/8"
181 mm
7 1/8"
181 mm
7 1/8"
181 mm
7 1/8"
181 mm
I 21 1/2"
546 mm
24 1/2"
622 mm
30 1/2"
774 mm
36 1/2"
927 mm
J 10 3/4"
273 mm
12 1/4"
311 mm
15 1/4"
387 mm
18 1/4"
464 mm
K 9 1/4"
235 mm
9 1/4"
235 mm
9 1/4"
235 mm
9 1/4"
235 mm
RIGHT SIDEVIEW
J
H
K
Remote Control
Options & Accessories
Description
FRBC Millivolt Batt. Remote ON/OFF
FRBTC Millivolt Batt. Remote T-Stat
FREC Direct Ignition/Millivolt 120V ON/OFF Remote
TMW Millivolt Wireless Wall Thermostat
TRW Millivolt Reed Switch Wall Thermostat
FWS-1 Direct Ignition/Millivolt Wall Switch
Venting Options Description
DVVK-4TS Top vent kit (HORZ.) - 4½" to 6" (114.3mm to 152mm) wall
thickness
DVVK-4T Top vent kit (horz.) - 8" to 12" (203mm to 305mm) wall thickness
DVVK-4R Rear vent kit (horz.) - 5" to 7" (127mm to 178mm) wall thickness
DVVK-4V Vertical vent kit
DVVK-4F Horizontal flex vent kit (4' FLEX)
DVVK-4RE Horizontal round termination (wall thickness up to 11 7/16")
DV822 Vinyl siding kit for DVVK-4RE
DVD32 DVD36 DVD42 DVD48
Input BTU/Hr Maximum 18,000 20,000 25,000 28,000
BTU/Hr Minimum (millivolt only) 14,000 14,000 18,000 20,000
KWH (Maximum) 5.3 5.9 7.3 8.2
(Minimum) 4.1 4.1 5.3 5.9
NAT.
Orifice
#46 (.081")
P-254
2.10 mm
P-288
#42 (.0935")
P-286
#39 (.0995")
P-285
Air Shutter Opening 1/16" (1.6mm) 1/16" (1.6mm) 3/16"(4.8mm) 1/8" (3.2mm)
LP
Orifice
#56 (.0465")
P-287
#55 (.052")
P-182
1.45 mm
P-208
#52 (.0635")
P-185
Air Shutter Opening 1/4" (6.3mm) 5/16" (7.9mm) 5/16" (7.9mm) 5/16" (7.9mm)
Height without standoff
32 3/4" (832mm) 32 3/4"(832mm) 34 3/4"(883mm) 34 3/4"(883mm)
Width 34" (864mm) 37" (940mm) 43" (1092mm) 49" (1245mm)
Depth 16 3/8" (416mm) 16 3/8" (416mm) 16 3/8" (416mm) 16 3/8" (416mm)
Gas Inlet Shutoff Valve (Pipe) 1/2 NPT 1/2 NPT 1/2 NPT 1/2NPT
NOTE: Air shutter settings
are factory minimum
settings. Some venting
co nf igu rat ion s may
require minor air shutter
adjustments for optimum
performance.
SPECIFICATIONS
FIREPLACE DIMENSIONS