Empire Products RH-25-6 Electric Heater User Manual


 
Page 912821-2-0903
1. STOP! Read the safety information to the left of this label.
2. Set thermostat to lowest setting.
3. Turn off all electric power to the appliance. (If applicable)
4. Remove access panel (front panel).
5. Push in gas control knob slightly and turn clockwise
to “OFF”. Do not force.
6. Wait ten (10) minutes to clear out any gas. Then smell for
gas, including near floor. If you smell gas, STOP! Follow
“B” in the safety information to the left of this label. If you
do not smell gas, go to the next step.
7. Remove the pilot access cover located on the combustion
chamber.
8. Find pilot - the pilot is attached to front of burner.
9. Turn gas control knob counterclockwise to “IGN”.
TO TURN OFF GAS TO APPLIANCE
3. Push in gas control knob slightly and turn clockwise
t o “OFF". Do not force.
A. This appliance has a pilot which must be lighted by
hand. When lighting the pilot, follow these instructions
exactly.
B. BEFORE LIGHTING smell all around the appliance
area for gas. Be sure to smell next to the floor because
some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your building.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire
department.
C. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or
turn by hand, don't try to repair it; call a qualified
service technician. Force or attempted repair may
result in a fire or explosion.
D. Do not use this appliance if any part has been under
water. Immediately call a qualified service techni-
cian to inspect the appliance and to replace any part
of the control system and any gas control which has
been under water.
LIGHTING INSTRUCTIONS
1. Set thermostat to lowest setting.
2. Turn off all electric power to the appliance. (If appli-
cable) If service is to be performed.
10. Depress and turn gas control knob counterclockwise
to “PILOT”. A spark is produced when gas
control knob is turned between “IGN” and “PILOT”.
Repeatedly depress and turn gas control knob between
“IGN” and “PILOT” until pilot is ignited. Continue to hold
the control knob in for about one (1) minute after pilot is
lit. Release knob and it will pop back up. If it goes out,
repeat steps 5 through 10.
If knob does not pop up when released, stop and imme-
diately call your service technician or gas supplier.
If the pilot will not stay lit after several tries, turn the gas
control knob to “OFF” and call your service technician or
gas supplier.
11. Attention! Gas control has INTERLOCK latching device.
When the pilot is initially lit and the safety magnet is
energized (pilot stays on) the INTERLOCK latching de-
vice becomes operative. If the gas control is turned to the
“OFF” position or gas flow to the appliance is shut off, the
pilot cannot be relighted until the safety magnet is de-
energized (approximately 60 seconds). There will be an
audible “click” when the safety magnet in the gas control is
de-energized. Pilot can now be relit. Repeat steps 5 through
10.
12. Turn gas control knob counterclockwise to
“ON”.
13. Turn on all electric power to the appliance. (If applicable)
14. Replace pilot access cover and access panel (front panel).
15. Set thermostat to desired setting.
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result
causing property damage, personal injury, or loss of life.
LIGHTING INSTRUCTIONS