Emerson ECD1500B Air Cleaner User Manual


 
0508082120/101203/C Page 4 Owner’s manual
Operating Instructions
Operating Instructions
1 INTRODUCTION
This manual provides instructions for the mounting/installation,
control and maintenance of the air cleaner. The safety
instructions should be read first.
2 PRODUCT DESCRIPTION
The air cleaner is provided with an Air Quality Analyzer. It
measures the local pollution continuously and adjusts the fan
speed accordingly. The analyzer is sensitive to pollution in
gaseous form that occurs in, for example, tobacco smoke.
2.1 Filter package
See fig. 1 on page 25
The polluted air is cleaned in three successive stages.
2.1.1 Prefilter [A]
The prefilter traps the coarser dust particles and other
pollutants.
2.1.2 Electronic filter [B]
The electronic filter has a very high efficiency and traps dirt
particles larger than 0.01 micron;
or (in case of a media filter):
2.1.3 Media filter [B]
The media filter is folded in such a way that it has a large
effective surface area. This gives a low air resistance and a high
dirt collection capacity.
2.1.4 Activated carbon filter [C]
The activated carbon filter adsorbs unpleasant smells.
2.2 Optional feature
2.2.1 Odor Free
If the air cleaner is provided with an Odor Free filter obnoxious
odors can be suppressed. The standard activated carbon filter
is replaced by the Odor Free filter.
3 MOUNTING/INSTALLATION
3.1 Technical specifications
3.2 Air cleaner mounting/installation
The air cleaner can be installed in several ways using different
installation kits.
For wall mounting use installation kit # F801 0193. This kit
is only suitable for single air cleaners.
For ceiling mounting of the air cleaners, use installation kit
# F801 0195. For a single air cleaner one set is required, for
the double air cleaner two sets are required.
For recessed ceiling mounting of the single air cleaner use
installation kit # F801 0196.
For the double air cleaner, use installation kit # F801 0197.
There are no components for mounting to the ceiling or wall in
these kits.
Ensure that the load capacity of the mounting devices is
sufficient to safely support the air cleaner. The weights of the
air cleaner are maximum 39.9 lbs. and 65.5 lbs. respectively.
For the single air cleaner on a pedestal, use pedestal installation
kit # F848 0384.
Use the materials prescribed during the installation. Connect the
air cleaner to power only after complete installation.
4MAINTENANCE
Maintain your air cleaner carefully and regularly. If poorly
maintained, it can be a fire hazard. Always disconnect the air
cleaner from power during maintenance and cleaning.
Adhere to the maintenance instructions and advice on filter
replacement.
Replace or clean the filters on time.
Only use manufacturer's original replacement parts.
Inspect the product for damages regularly. The safety features
should be checked regularly for proper functioning and, if
required, be repaired immediately.
The cord should be checked regularly and, if damaged, replaced
by a qualified service person.
4.1 Filter replacement/cleaning frequency
Filter replacement/cleaning frequency depends on local
conditions, the fan speed selected and the operating time of the
air cleaner. The Service Indicator can be used to help determine
the filter replacement/cleaning frequency. See Program Settings
step 1.
A crackling or snapping sound will be heard occasionally during
use of the air cleaner. This is normal and is caused by high
voltage arcing in the filter. Cleaning the electronic filter is
necessary when the crackling or snapping is heard frequently.
Filter replacement/cleaning may be done as described in the
technical repair section.
4.2 Cleaning the outside of the air cleaner
Wipe the outside of the air cleaner with a moist cloth. Do not
use cleaning products that contain ammonia or abrasives. The
air cleaner is not resistant to organic solvents, such as benzene,
etc. It is possible that the Air Quality Analyzer temporarily
reacts abnormally with exposure to cleaning agents.
Single Double
Dimensions 24.8x24.4x11.4 in. 24.8x41.3x11.4 in.
Max. built-in height 8.3 in. 8.3 in.
Weight max. 39.9 lbs. max. 65.5 lbs.
Power consumption:
- electronic
- media
130 W
118 W
225 W
222 W
Voltage 115V, 60Hz 115V, 60Hz