Emerson CF670CK00 Fan User Manual


 
Repair Parts Listing
Part Numbers
Key Model No. Model No. Model No. Model No.
No. Description CF670OB00 CF670WB00 CF670CK00 CF670BQ00
* Hanger Ball Assembly, 761655-9 761655-20 761655-23 761655-19
Consisting of:
1 Hanger Bracket
2 Hanger Ball
3 Downrod
* Parts Bag Containing: 762449 762449 762449-1 762449
4 Wire Connector (3)
5 Threaded Stud (2)
6 Lockwasher, #8 (2)
7 Knurled Knob (2)
8 Clip, Hairpin
9 Pin, Clevis
10 Screw, M5 x 6mm (16)
11 Pendant, Wood, Small
12 Pendant, Wood, Large
13 Coupling, Chain (2)
14 Flange Screw with
lockwasher, M6 x 14mm (1)
15 Cover, Ceiling 762456 762456-1 762456-2 762456-3
16 Cover, Coupling 762463 762463-1 762463-2 762463-3
17 Blade (set of 5) 762445 762445 762445-1 762445
18 Flange (set of 5) 762447 762447-1 762447-2 762447-3
19 Harness, Wiring 762450 762450 762450 762450
20 Housing, Switch 762455 762455-1 762455-2 762455-3
Owner's Manual BP7271 BP7271 BP7271 BP7271
Before discarding packaging material, be certain all parts have been removed.
HOW TO ORDER REPAIR PARTS
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION:
PART NUMBER NAME OF ITEM
PART DESCRIPTION MODEL NUMBER
The model number of your Fan will be found on a label attached to the top housing.
For repair parts, phone 1-800-654-3545.
Part No. F40BP72710000 Printed in China 03/04 Form No. BP7271
Trouble Shooting
TROUBLE PROBABLE CAUSE SUGGESTED REMEDY
1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers.
2. Loose power line connections to the fan, or loose 2. Check line power connections to fan and switch wire
switch wire connections in the switch housing. connections in the switch housing.
WARNING: Make sure main power is turned off.
3. Reversing switch in neutral position. 3. Make sure reversing switch position is all the way to one side.
2. Fan sounds noisy. 1. Blades not attached to fan. 1. Attach blades to fan before operating.
2. Screws securing fan blade flanges to motor 2. Check to make sure the screws which attach the fan flanges to the
are loose. motor are tight.
3. Wire connectors inside switch housing rattling. 3. Check to make sure wire connectors in switch housing are not
rattling against each other or against the interior wall of the switch
housing.
WARNING: Make sure main power is turned off.
4. Screws holding blades to flanges are loose. 4. Tighten screws securely.
3. Fan wobbles 1. Setscrew in motor coupling is not tightened 1. Raise coupling cover and tighten setscrew securely.
excessively. securely.
2. Setscrew in the hanger ball/downrod assembly is 2. Tighten the setscrew in the hanger ball/downrod assembly.
loose.
3. Screws securing fan blade flanges to motor are loose. 3. Check to be sure screws which attach the fan blade flanges to the
motor are tight.
4. Fan blade flanges not seated properly. 4. Check to be sure the fan blade flanges seat firmly and uniformly to
the surface of the motor. If flanges are seated incorrectly, loosen
the flange screws and retighten according to the procedure in the
section on "How to Put Your Ceiling Fan Together".
5. Hanger bracket and/or ceiling outlet box is not 5. Tighten the hanger bracket screws to the outlet box, and/or secure
securely fastened outlet box.
6. Fan blades out of balance. 6. Interchanging an adjacent (side-by-side) blade pair can redistribute
the weight and result in smoother operation.
WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER
BEFORE TROUBLE SHOOTING YOUR FAN.
15
4
16
5
8
9
18
1
2
3
7
6
17
10
14
12
13
11
20