Emerson CF552GBZ00 Fan User Manual


 
8
U.L. Model No.: CF552
If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.
1. Connect the green grounding lead from the hanger
ball and the green grounding lead from the hanger
bracket to the grounding conductor of supply (this
may be a bare wire or wire with green colored
insulation). Securely connect wires with wire
connectors supplied.
NOTE: If you are using an Emerson Light Fixture
with your fan, see Light Fixture Owner’s Manual
for wiring.
How to Wire Your Ceiling Fan
To avoid possible electrical shock, be sure electricity
is turned off at the main fuse box before attempting
installation.
NOTE: If you are not sure if the outlet box is
grounded, contact a licensed electrician for advice,
as it must be grounded for safe operation.
NOTE: CEILING COVER
OMITTED FOR CLARITY.
GROUND
WIRE
LISTED
WIRE
CONNECTOR (3)
GREEN WIRE
(GROUND) FROM
HANGER BRACKET
GREEN WIRE
(GROUND) FROM
HANGER BALL
WHITE SUPPLY
(NEUTRAL)
WHITE FAN
WIRE
BLACK SUPPLY
(HOT)
BLACK AND BLUE
FAN WIRES
Figure 4
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.
Figure 14
WARNING
!
WARNING
!
2. Securely connect the fan motor white wire to the
supply white (neutral) wire using wire connector
supplied (Figure 14). Securely connect the fan
motor black wire and blue wire to the supply black
(hot) wire using wire connector supplied (Figure
14). After connections have been made, turn leads
upward and carefully push leads into the outlet box,
with the green equipment-grounding conductor and
white grounded neutral conductor on one side of
the outlet box and the black and blue ungrounded
conductors on the other side of the outlet box.
3. Screw the two threaded studs (supplied) into the
tapped holes in the hanger bracket.
4. Lift the ceiling cover up to the threaded studs and
turn until studs protrude through the holes in the
ceiling cover (Figure 15).
5. Secure the ceiling cover in place by sliding
lockwashers over the threaded studs and installing
the two knurled knobs (supplied). (Figure 15).
Tighten the knurled knobs securely until the ceiling
cover fits snugly against the ceiling and the hole in
the ceiling cover is clear of the downrod. Your fan
is now wired to be turned on and off from the fan
switch.
6. Cut the 3-speed switch pull chain to a desired
length (optional). Connect the die-cast pendant
(supplied) to the 3-speed switch pull chain by
sliding the die-cast pendant (small hole first) onto
the pull chain. Attach the chain coupling to the end
of the chain and allow the die-cast pendant to fall
down over the coupling.
THREADED
STUDS (2)
KNURLED
KNOBS (2)
CEILING
COVER
LOCKWASHERS
(2)
To avoid possible fire or shock, make sure that the
electrical wires are completely inside the outlet box
and not pinched between the ceiling cover and the
ceiling.
Figure 15
WARNING
!