Emerson CF2300WB01 Fan User Manual


 
15. Securely attach the hanger bracket to the outlet
box using the two screws supplied with the outlet
box (Figure 11).
6
11. Reinstall the hanger ball on the downrod as
follows. Route the motor leads through the hanger
ball and slide the hanger ball over the downrod
(Figure 7). Install the pin through the holes at the
top of the downrod and slide the hanger ball up
the downrod, aligning the ball so the pin is cap-
tured in the groove in the top of the hanger ball.
Pull the hanger ball up tight against the pin and
securely tighten the setscrew in the hanger ball. A
loose setscrew could create fan wobble.
12. Use three 10-32 x 3/8" pan head screws and flat
washers (supplied) to secure flange to blade
(Figure 8). Repeat for the remaining four blades.
13. Use the 10 round recessed holes in the motor hub
marked with "5" and install the five blade assemblies
(blades ordered separately) in accordance with
Step 14.
14. Attach one blade assembly to the motor hub using
two 10-32 x 5/8" oval head screws (supplied)
(Figure 9). Do not tighten completely at this time.
Install remaining blade assemblies in the same
way. Gently snug all flange screws to the motor
hub, working around the hub in a clockwise
sequence. Next, securely tighten all flange screws,
again working in a clockwise sequence. Failure to
follow this procedure could result in fan wobble.
This completes the blade installation.
SETSCREW
DOWNROD
PIN
HANGER BALL
CEILING COVER
Figure 7
MOTOR
HUB
10-32 x 5/8"
OVAL HEAD SCREWS
(2 PER BLADE
ASSEMBLY)
10-32 x 3/8" PAN HEAD
SCREW (3)
FLAT WASHER (3)
BLADE
BLADE
FLANGE
Figure 8
Figure 9
CEILING
FLOOR
AT LEAST
7'
Figure 10
It is critical that the pin in the hanger ball is properly
installed and the setscrew securely tightened.
Failure to verify that the pin and setscrew are
properly installed could result in the fan falling.
WARNING
!
To reduce the risk of personal injury, do not bend the
blade flanges when installing the blades or cleaning
the fan. Do not insert foreign objects between rotat-
ing fan blades.
WARNING
!
The fan must be hung with at least 7' of clearance
from floor to blades (Figure 10).
WARNING
!
The outlet box must be securely anchored and capable
of withstanding a load of at least 50 lbs.
WARNING
!
To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked acceptable for
fan support, and use screws supplied with outlet
box. Most outlet boxes commonly used for support
of light fixtures are not acceptable for fan support
and may need to be replaced. Consult a qualified
electrician in in doubt.
WARNING
!
Hanger bracket must seat firmly against outlet box. If
the outlet box is recessed, remove wall board until
bracket contacts box. If bracket and/or outlet box are
not securely attached, the fan could wobble or fall.
WARNING
!