Emerson CF1ORB01 Fan User Manual


 
7
OUTLET
BOX
HANGER
BRACKET
HANGER BALL/
DOWNROD ASSEMBLY
NOTE: CEILING COVER,
SUPPLY WIRES AND
FAN WIRES OMITTED
FOR CLARITY.
Figure 14
To avoid possible fire or shock, do not pinch wires
between the hanger ball/downrod assembly and the
hanger bracket.
WARNING
!
How to Wire Your
Ceiling Fan
If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.
1. Connect the green grounding lead from the hanger
ball and the green grounding lead from the hanger
bracket to the grounding conductor of supply (this
may be a bare wire or wire with green colored
insulation) (Figure 15). Securely connect wires
with wire connector supplied.
NOTE: If you are using an Emerson Light Fixture
with your fan, see Light Fixture Owner’s Manual
for wiring.
To avoid possible electrical shock, be sure electricity
is turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is
grounded, contact a licensed electrician for advice,
as it must be grounded for safe operation.
WARNING
!
NOTE: CEILING COVER
OMITTED FOR CLARITY.
SUPPLY
GROUND
WIRE
LISTED
WIRE
CONNECTOR (3)
GREEN WIRE
(GROUND) FROM
HANGER BRACKET
GREEN WIRE
(GROUND) FROM
HANGER BALL
WHITE SUPPLY
(NEUTRAL)
WHITE FAN
WIRE
BLACK SUPPLY
(HOT)
BLACK AND BLUE
FAN WIRES
Figure 15
2. Securely connect the fan motor white wire to the
supply white (neutral) wire using wire connector
supplied (Figure 15). Securely connect the fan
motor black wire and blue wire to the supply black
(hot) wire using wire connector supplied
(Figure 16). After connections have been made,
turn leads upward and carefully push leads into the
outlet box, with the white and green leads on one
side of the outlet box and the black and blue leads
on the other side of the outlet box.
3. Screw the two 1-1/4” threaded studs (supplied)
into the tapped holes in the hanger bracket
(Figure 16).
4. Lift the ceiling cover and the ceiling cover trim up
to the threaded studs and turn until studs protrude
through the holes in the ceiling cover and trim
(Figure 16).
5. Secure the ceiling cover and trim in place by
sliding lockwashers (supplied) over the threaded
studs and installing the two knurled knobs
(supplied) (Figure 16). Tighten the knurled knobs
securely until the ceiling cover fits snugly against
the ceiling and the hole in the ceiling cover is clear
of the downrod. Your fan is now wired to be turned
on and off from the fan switch.
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.
WARNING
!
CEILING
COVER
TRIM
CEILING
COVER
1-1/4"
THREADED
STUD
LOCKWASHER
KNURLED KNOB
To avoid possible fire or shock, make sure that the
electrical wires are completely inside the outlet box and
not pinched between the ceiling cover and the ceiling.
WARNING
!
Figure 16