Emerson CF144CRM00 Fan User Manual


 
UL Model No.: CF144 & CF152
13
Fan/Light Fails to Operate
Check that the speed switch on the
fan is set to HIGH (
....
) speed.
Check that the light switch is on.
Check that the battery is good
(red indicator light should light when
any button is pressed).
Check that the receiver is wired
properly.
Check that code switches in the
remote control and receiver are set in
the same position.
Short Range
If the remote control operates the fan
when close to it, but does not operate
it at a distance of 40 feet, try placing
the antenna wire outside of the ceiling
cover.
Remote Control Trouble Shooting
Ceiling Fan Trouble Shooting
TROUBLE PROBABLE CAUSE SUGGESTED REMEDY
1.Fan will not 1. Fuse or circuit breaker 1. Check main and branch
start. blown. circuit fuses or circuit breakers.
WARNING: Make sure
main power is turned off.
2. Loose power line 2. Check line power connections
connections to the fan. to fan.
3. Fan/Light remote control is OFF. 3. Turn ON Fan/Light remote control.
2.Fan sounds 1. Blades not attached to fan. 1. Attach blades to fan before
noisy. operating.
2. Screws securing fan blades 2. Check to make sure the screws
to motor are loose. which attach the blades to the
motor are tight.
WARNING: Make sure main
power is turned off.
3.Fan wobbles 1. Screws securing fan blades 1. Check to be sure screws which
excessively. to motor are loose. attach the fan blade to the
motor are tight.
2. Fan blades are not seated 2. Check to be sure that the
properly. screws securing the fan
blades seat firmly.
3. Fan blades out of balance. 3. Interchanging an adjacent (side
by-side) blade pair can
redistribute the weight and result
in smoother operation.
Or use supplied balancing kit to
balance blades.
WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX
OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN.
!
!
!
BP7407 44" & 52" Curva Sky 1/11/10 9:54 PM Page 13