Emerson 1F82-261 Heat Pump User Manual


 
Size: 8.5" x 11"
Job
#: WRD
G_115963
File Name: 115963_80SeriesHPmpSS_Rev.ai
Printing & Finishing: 4/cProc-Offset
Colors:
CMYK DIE
Printout Size
100%
Updates: jd10.18.06, jd10.20.06,
jd11.29.06, jd12.01.06, kd12.07.06
BBpff12.15.06
This printout is for indicating
color breaks only.
Do not use for color matching.
Do not measure for accuracy.
Revision: 06
Time:
4pm
The Emerson logo is a trademark and
a service mark of Emerson Electric Co.
The Emerson logo is a trademark and
a service mark of Emerson Electric Co.
80 Series
®
Heat Pump Thermostats
White-Rodgers
WR-3583-1
St. Louis, Missouri Markham, Ontario
314-553-3600 905-201-4701
www.white-rodgers.com
Programming (1F82-261)
Choice of 5/1/1 day programmable or
non-programmable
4 time and 4 temperature settings per
program (heat & cool)
Energy savings up to 33%
Patented pre-programmed software
simplifies time and temperature
programming
Display
60% larger LCD with improved contrast for
easier reading
Lighted display for easier
low-light viewing
Comfort & Convenience
Permanent program retention during
power loss, no batteries needed
Indefinite setpoint Hold or programmable
timed Hold up to 8 hours (1F82-261)
Air filter change indicator
Simple menu to activate optional features
Temporary temperature override until next
program period (1F82-261)
Soft-touch keypad
Maintains room temperature differential
within +/- 1°
Display temperature recalibration (+/- 4°)
Performance
Selectable Energy Management Recovery
(1F82-261)
Powerful next-generation microprocessor
Meets ENERGY STAR
®
specifications (1F82-261)
Meets California Building Code, Title 24
(1F82-261)
Fast (FA) or slow (SL) heating cycle anticipation
B or O terminal (selectable)
Compressor lockout protection (optional)
Dimensions
3.8"H x 6.1"W x 1.1"D
Electrical Specifications
Rating
20 to 30 VAC, 50/60 Hz or DC
0.05 to 1.2 Amps (load per terminal)
1.5 Amps maximum load (all terminals combined)
Standard Systems
Heat Pump—2 stage heat, 1 stage cool
Single stage heat pump
Thermal Specifications
Setpoint Temperature Range:
45° to 90°F (7° to 32°C)
Rated Differential:
0.6° to 1.6°F with adjustable anticipation
Operating Ambient Temperature:
32° to 105°F (0° to 40°C)
Operating Humidity Range:
90% non-condensing maximum
Shipping Temperature Range:
-4° to 150°F (-20° to 65°C)
Accessories
Wall Plate F61-2500 (7.6"W x 4.8"H)
Thermostat Guard F29-0231
(For additional guard options refer
to White-Rodgers catalog)
For Additional Information
Visit www.white-rodgers.com
R YW2
B/O
G E LC
24V Hot 24V
Common
Auxiliary
Heat
Relay
Compressor
Relay
(Stg. 1)
Reversing
Valve
Emergency
Heat Relay
System
Monitor
Blower/Fan
Terminal Designations
1F82-261
Heat Pump
5/1/1 Day Programmable
1F89-211
Heat Pump
Non-Programmable
• 5/1/1 Day Programmable or Non-Programmable • Hardwired
Programs
Program
Options
Programmable
Fan
Energy
Star
Diplay
Size
(sq. in.)
Cool
Savings
Warranty
(Years)
Model
Number
Model
Gas/Oil/
Electric
3 Wire
Zone
Valve
Thermostat
Power
Source*
Millivolt
Compatible
Applications
Selectable Performance Features
Comfort & Convenience Features
Stages Heat/Cool
by System
Single
Stage
Multi-
Stage
Heat
Pump
Auto
Changeover
Program
Override
Memory
Back-up
P-Permanent
B-Battery
Lighted
Display
Energy
Management
Recovery
Alkaline
Battery Life
(Years)
Furnace Lockout
Ignition
Module Reset
2/1
2/1
1F82-261
1F89-211
5+1+1
Ø
H
H
1.8
1.8
2+
2+
P
P
1
1
✓✓
* H = Hardwire (Requires Common)