8
Modelling lamps and fuses for 110 V & 230 V
Unit Modelling lamp 110V Modelling lamp 230V Socket Fuse
D-Lite 2 it 100W / 23006 100W / 23002 E27 2.5AF / 19035
D-Lite 4 it 100W / 23006 100W / 23002 E27 2.5AF / 19035
Programmable features - Reset English
Modelling lamp features & setup
How to „Reset“ the D-Lite it
In case you need to „RESET“ the D-Lite it to the manufacturer settings please follow the steps below:
1. Switch the unit “off“
2. Press both flash power up / down buttons (10) at the same time and switch the unit on
3. The Digital LED multi display (6) flashes in fast mode
4. Do not continue to press the buttons, the resetting procedure is completed
Modelling lamp modes
* Do not use energy saving lamps
>
Setting: • Press “Modelling” button to set Modelling lamp ON to proportional mode, max.
mode, min. mode, or OFF
• Press “Modelling” up or down button to set Modelling lamp to free mode, press
“Free/Prop” to switch Modelling lamp OFF.
> LED Indication: • LED is on: only in proportional mode.
• LED is off: in min. / max. / off mode.
!
• Please use only original ELINCHROM modelling lamps with a maximum power
of 100W ( effective 150W).