Elinca FX 100 Home Safety Product User Manual


 
9
10
Photocell receptor
5
Test and ready
Cell (9)
Modellling
light controls
Power display
The actual ash power is shown in a f-stop compatible format.
The power range is 5 f-stops. The digital display, provides continuous power indication of the ash
and modelling lamp. The controls cover a continuous output range from full power 1/1 to 1/16th in
1/10th, f-stop intervals.
During charging or discharging, the display "ashes".
Note:
The "Style 100 FX and 400 FX" units have an integrated discharge system, protected by a thermic switch.
To avoid overheating, lower power settings of more than 2f-stop, can be discharged manually by releasing the
ash with the «Test» touch button.
The photocell is actived when the green LED (on the touch pad 9) is illuminated.
When switched ON, the unit can be remotely triggered by another ash unit !
The Style FX photocell is specially designed to work under ambiant light conditions in your studio.
Direct light or other strong light sources may reduce the sensitivity of the cell.
In difcult situations e.g. blinding, sunlight or obstacles, the additional cell with 5 m cord
(extensions available) solves most problems.
Digital power display
Photocell