Elektra Beckum P 5500 M Plumbing Product User Manual


 
11
ENGLISH
If the pump capacity lessens clean
suction strainer and filter cartridge (if
installed), replace if necessary.
7.2 Danger of freezing
A
Caution!
Frost damages the pump and
accessories, as both always contain
water!
When there is danger of freezing,
dismount equipment and accesso-
ries and store at a freeze-proof loca-
tion (see below).
7.3 Equipment dismounting
and storing
1. Switch equipment OFF and unplug.
2. Open pressure line (open tap or
spray nozzle) and drain water com-
pletely.
3. Drain pump completely; to do so
remove the drain plug from the
pump
4. Disconnect suction and pressure
lines from the equipment.
5. Store equipment in a frost-free
space (at least 5 °C).
A
Danger!
Prior to all servicing:
Switch Off.
Unplug.
Ensure that pressure is relieved
from equipment and connected
accessories.
8.1 Fault finding
Pump does not run:
No mains voltage.
Check cables, plug, outlet and
mains fuse.
Mains voltage too low.
Use only extension cables with
sufficient lead cross section (see
"Technical Specifications").
Motor overheated, motor protection
relay tripped.
After cooling off the pump will
switch ON again.
Ensure sufficient ventilation, keep
vent slots clear.
Observe max. temperature of the
pumped medium.
Motor hums but does not start.
With the motor switched OFF, put
screwdriver or similar through the
fan cover's vent slots and turn the
fan.
Pump blocked or out of order.
Disassemble pump and clean.
Clean diffusor, replace if neces-
sary.
Clean impeller, replace if neces-
sary.
Pump does not prime correctly or
runs very noisily:
Lack of water.
Ensure there is a sufficient water
supply.
Suction line leaky.
Seal suction line, tighten screw
fittings.
Suction head too high.
Observe max. suction head.
Install check valve, fill suction line
with water.
Suction strainer (accessory)
blocked.
Clean, replace if necessary.
Check valve (accessory) blocked.
Clean, replace if necessary.
Water leaks between motor and
pump, Duocone seal worn.
Replace Duocone seal.
Pump blocked or out of order.
see above.
Pressure too low:
Suction line leaky or too much suc-
tion head.
see above.
Pump blocked or out of order.
see above.
A
Danger!
Repairs to electric tools must
only be carried out by a qualified
electrician!
Electric tools in need of repair can be
sent to an authorised service center in
your country. See spare parts list for
address.
Please attach a description of the fault to
the electric tool.
For shipping:
Drain pump completely (see "Equip-
ment dismounting and storing").
Ship equipment in original packing,
if possible.
The packaging of the pump can be
100 % recycled.
Worn out power tools and accessories
contain considerable amounts of valua-
ble raw and plastic materials, which can
be recycled.
These instructions are printed on chlo-
rine-free bleached paper.
For this equipment the following acces-
sories are available at specialist dealers.
3
Note:
Illustrations and stock numbers
can be found at the end of these instruc-
tions.
A Pump Installation Package,
complete with double nipple, check
valve, filter short, washable filter
cartridge, spiral hose assembly
1 m, thread sealing tape.
B Hydromat HM 1,
for automatic starting when water is
drawn and stopping when no water
is drawn, keeps the pump from run-
ning dry.
C Hydrostop,
for automatic stopping when there
is a lack of water, prevents the
pump from running dry.
D Dry-running Stop Switch,
with 10 m cable, keeps the pump
from running dry when pumping
from tank, pool, etc.
E Spiral Hose 1"
1) 1 m assembly, with quick
release screw fitting at both
ends;
2) 4 m, complete with quick
release screw fitting and
strainer with foot valve;
3) 7 m, complete with quick
release screw fitting and
strainer with foot valve.
F Filter, 1" connection, short,
complete with washable plastic fil-
ter cartridge.
G Disposable Filter Cartridge, short,
for mechanical preliminary filtering
of sand.
H Washable Filter cartridge, short,
for mechanical preliminary filtering
of sand, reusable.
I Activated Carbon Filter Cartridge,
short,
for use with chlorous water,
removes odours or discolouring.
J Filter Cartridge Poly, short,
filled with polyphosphate, for calcif-
erous water supplied to water heat-
ers.
K Pipe Nipple 150 mm, 1" male at
both ends, galvanized, to connect
pump and filter.
L Double Nipple, 1" male at boths
ends.
M Check Valve 1" female, prevents
water backflow and pump running
dry.
N Thread Sealing Tape, 12 m roll.
8. Trouble Shooting
9. Repairs
10. Environmental Protection
11. Available Accessories