Elation Professional 30 Home Safety Product User Manual


 
Elation Professional - www.elationlighting.com - Opti Tri 30 Instruction Manual Page 13
Opti Tri 30 Cleaning
Due to fog residue, smoke, and dust cleaning the internal and exter-
nal optical lenses must be carried out periodically to optimize light
output.
1. Use normal glass cleaner and a soft cloth to wipe down the
outside casing.
2. Clean the external optics with glass cleaner and a soft cloth
every 20 days.
3. Always be sure to dry all parts completely before plugging
the unit back in.
Cleaning frequency depends on the environment in which the fixture
operates (i.e. smoke, fog residue, dust, dew).
Opti Tri 30 Trouble Shooting
Listed below are a few common problems the user may encounter,
with solutions.
Unit not responding to DMX:
1. Check that the DMX cables are connected properly and are
wired correctly (pin 3 is “hot”; on some other DMX devices
pin 2 may be ‘hot’). Also, check that all cables are connected
to the right connectors; it does matter which way the inputs
and outputs are connected.
Unit does not respond to sound:
1. Quiet or high pitched sounds will not activate the unit.
Opti Tri 30 7 Channel Mode - DMX Values and Functions
Channel Value Function
1 RED
1 - 255 0% - 100%
2 GREEN
1 - 255 0% - 100%
3 BLUE
1 - 255 0% - 100%
4 1 - 255 COLOR MACROS
PLEASE SEE 1 CHANNEL MODE
5 0 - 15 NOTHING
16 - 255 STROBING/SPEED CONTROL
6 MODE
0 - 31 RGB USING CHANNEL’S 1, 2, & 3
32 - 63 DIM - BRIGHT
64 - 95 BRIGHT - DIM
96 - 127 DIM - BRIGHT - DIM
128 - 159 COLOR MIXING
160 - 191 3 COLOR CHANGE
192 - 223 7 COLOR CHANGE
224 - 255 SOUND ACTIVE
7 MASTER DIMMER
1 - 255 0% - 100%
Channel 1, 2, and 3 will not work, when Channel 4 is being
used.
When using Channel 6, Channel 5 will control the speed of the
color changing.
Elation Professional - www.elationlighting.com - Opti Tri 30 Instruction Manual Page 14