Ei Electronics Ei 261EN Carbon Monoxide Alarm User Manual


 
(7) Never use a gas cooker or a barbecue for home heating.
(8 Children should be warned of the dangers of CO poisoning and instructed never to touch, or inter-
fere with the CO Alarm. Do not allow small children to press the test/hush button as they could be
subjected to excessive noise when the unit alarms.
(9) Leaving windows or doors slightly open (even a few inches) will significantly reduce the risk of high
levels of CO occurring. The high levels of draught-proofing in modern houses reduces ventilation
and can allow dangerous gases to build up.
(10) Install CO Alarms in all the areas recommended in this leaflet.
(11) Recognise that CO poisoning may be the cause when family members suffer from “flu-like” symp-
toms when at home but feel better when they are away for extended periods.
9. TECHNICAL SPECIFICATION
Operating Voltage : 230±10% VAC, 50Hz
Power : 1 Watt, (60 mA)
Power on Indicator : Green Light on
Sensor : Electrochemical Sensor
CO Sensitivity : Meets BS EN 50291: 2001.
Unit operates as per Table B above.
Electrical Safety : Complies with relevant sections of EN 60335-1: 1994
24
B15404-R0-261EN-UC-ENG 31/5/07 2:01 PM Page 26