Ei Electronics Ei169 Smoke Alarm User Manual


 
Shannon Free Zone, Shannon, Co. Clare, Ireland.
Ph.+353 61 471277 Fx.+353 61 471053
Email. eielectronics@eiltd.ie
Web: www.eielectronics.com
E & OE As our policy is one of continuous product development, we reserve the right to alter product details without prior notice. Ei169 DataSht RevA
Model Ei169
Placement Information
Alarms should be placed in accordance with the general guidelines shown in
the diagram above. These recommendations are based on the problem of
areas of “dead air” close to corners of rooms and apexes of ceilings, which
could result in the prevention of smoke reaching the smoke detector
Important Precaution:
Do not install the actual smoke/heat
alarm itself in new or renovated
buildings until all work is completed
(including floor coverings) and the
building has been fully cleaned.
The wiring can be installed when
appropriate. (Excessive dust and
debris from building work can
contaminate the smoke chamber
and cause problems, and it will also
invalidate the guarantee). If it must
be installed, cover it completely,
particularly around the edges, with
a dust cover (eg. a plastic bag),
until all cleaning is finished..
Connect wires to the unit as in
wiring diagram. All wiring must
comply with local codes.
Technical Specification
Sensor Optical or Ionisation
Sensitivity: Complies with BS 5446 Part 1:
2000
Source: Americium 241 (for Ei171 only)
Airspeed: Essentially immune to the effect
of airspeed.
Button Test: Tests strobe, vibration pad and
panel
Fault Monitor: Open/short circuit
Supply Voltage: 230V AC
Battery back up: Sealed Rechargeable lead acid
battery
Auxiliary socket: Provides 12V/200mA in alarm
Power-On Indicator: Continuous green LED
Alarm: Xenon tube strobe (1Hz)
Temperature Range: 0 to 40°C
Humidity Range: 0% to 90% Relative Humidity
Interconnect: Up to 12 interconnected
Ei151/154/156 smoke/heat alarms
Fixing: Screw fixings supplied
Plastic material: UL94VO flame retardant
Warranty: 5 year (limited) warranty
Approvals: BS 415:1990 electrical safety
Specifications are subject to change