Ecom Instruments Lite-Ex LED 30 Home Safety Product User Manual


 
16
16
4.2 Special conditions for use in
areas of Zone 0 or 21
1. The Lite-Ex LED 30 is only certified
and permitted for used in Zone 0 or 21
providing it is secured to the user with
the provided lanyard/wrist strap.
2. The torch unit should be prevented
from being dropped.
3. The torch unit must not be left any-
where or stored in Zones 0 or 21.
4.3 Special conditions in dusty
Ex-areas
1. After each change of batteries, the
torch must be blown out or internally
cleaned with a suitable device.
2. The sealing ring must be checked for
any deterioration or damage.
5. Ex-Data
EC Certificate of Conformity No.:
ZELM 02 ATEX 0104
Ex-Designation:
II 1 G EEx ia IIC T4
II 2 D T90°C IP 52
Approved for Zone 2, 1and 0; equipment
group II, gas group IIC;
explosive gases, vapours or fog,
temperature class T4.
Approved for Zone 22 and 21; equipment
group II, explosive dusts; T90°C
6. Technical Data
Ambient operating
temperature Ta: -20°C ... +50°C
Storage temperature: -20°C ... +60°C
Batteries /
power supply: 3 x LR1 as per IEC
(see table of approved battery types)
BAL Lite-Ex LED 30.indd 16 15.10.2007 16:36:20 Uhr