Earlex SC125 Carpet Cleaner User Manual


 
Earlex Ltd., Earlex House, Moorfield Road, Slyfield Industrial Estate, Guildford, Surrey. GU1 1RU.
Tel: +44 (0) 1483 454666. Fax: +44 (0) 1483 454548. email: enquiries@earlex.co.uk Website: www.earlex.co.uk
MAINS CONNECTION
Your unit has been supplied with a mains lead with a fitted plug. This is identified by the fuse holder in the base of the plug. Please read the following
safety instructions before use.
1 If the fitted plug is cut off from the mains lead then the plug must be disposed of safely. NEVER under any circumstances insert such a plug into a
13 amp socket.
2 NEVER under any circumstances use the appliance or mains lead without the fuse cover fitted. This is the little cover fixed into the base of plug to
hold the fuse in place.
3 If you lose the fuse cover then please contact any electrical dealer for a replacement or ring our helpline.
4 A replacement fuse must be rated at 13 amp. These must be manufactured and approved to BS 1362.
5 IF IN ANY DOUBT PLEASE CONSULT AN ELECTRICIAN.
If you need to fit a plug to the mains lead, this should be fitted in accordance with the wiring instructions below, and will need to be used with a 13
amp fuse. If in any doubt consult an electrician.
WARNING - THIS APPLIANCE MUST BE EARTHED. If you are using an extension lead it must be rated at a minimum of 10 amps and fully unwound.
Do not operate with a lead rated at less than 10 amps as this will cause premature failure of the element which is not covered by the guarantee.
As the colours of the wires in the mains Iead of this appliance may not correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or
by the earth symbol, or coloured green or green and yellow.
The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black.
The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red.
GUARANTEE
This product is guaranteed for a period of 24 months against faulty materials and workmanship. Whilst every possible care is taken
by Earlex to ensure that our products leave the factory in good working order, Earlex cannot under any circumstances accept liability
for problems or damage caused by their subsequent use. It is the responsibility of the user to ensure that surfaces to be treated,
cleaned or stripped are suitable for steam.This guarantee does not effect your statutory rights. This guarantee excludes the use for
hire purposes. In the event of a fault occuring please contact our helpline before returning the unit to our Service Department at the
address below together with a copy of your purchase receipt. All repairs will be dealt with speedily.
EC Declaration of Conformity
We declare that the units: SC75, SC76, SC125, SC150 & SC165 conform to: 73/23/EEC, EN60335-1, EN60335-2-15
& 89/336/EEC, EN55014-1, EN 55014-2, EN 61000-3-2, EN61000-3-3.
Tim Hopper -Technical Director
OTHER PRODUCTS FROM EARLEX
PR9 Autofeed
®
Cordless Painting System - Portable battery operated
paint rolling system. It has a 3 litre paint reservoir and 23cm (9”) roller and
automatically feeds paint to the roller head.
Easy to use the PR9 provides enough capacity to apply one coat to a 3.6m
x 2.7m (12’ x 9’) room without having to refill.
PRA1 1.4m extension pole - Used in conjunction with the PR9 the PRA1
allows you to paint ceilings and high areas without the use of step ladders
or having to move furniture.
WD1000 - Combivac Workshop Vacuum & Blower. The 1000W motor
provides a powerful suction and blowing facility which is ideal for use
around the workshop, garage, caravan, car, garden and home. The 20 litre
recovery tank has 12 litres wet capacity and is designed for the rough and
tumble of every day use. The Combivac has on board storage facilities for
its accessories, 6 metres of working length and a two year guarantee.
There is also a variety of additional accessories available for use with the
Combivac.
WD1200 - CombiPower Vac - Incorporating a powerful 1200W motor and
onboard power tool socket for all types of power tools. Features a dust
extraction system, automatic start-up and delayed shut-off when used with
a power tool. It sucks up liquid spills and dust, and blows away leaves and
dust. Ideal for use in the workshop and garden.
HG1600K - Heat Gun Kit. The Earlex Heat Gun Kit offers a 1600 Watt
heat gun in a strong carry case and includes a range of useful accessories.
With two heat settings the heat gun can be set at 350˚C or 520˚C. It is pro-
vided with a selection of four nozzles, three shavehooks and a scraper to
suit different tasks and it all stores away conveniently in the carry case.
ASG55 Super Sprayer 55. Sprays a 6’ x 6’ fence panel, on average in
5 minutes!
55W Electric Airless Spray Gun, ideal for spraying wood preservatives,
shed & fence treatments, water & solvent based paints. Ideal for sheds,
fences and trellis. It has a 1 litre capacity, easy-grip handle that provides
good balance and control. Hardened steel cylinder and stainless steel pis-
ton for longer life. Kit includes 0.6mm & 1mm nozzles & lubricating oil.
Check the Earlex website for up to date information on what you can spray.
Spray Station - HVLP (High Volume Low pressure) Complete paint
spraying system - Ideal for spraying large or detailed jobs with equal
ease. Fast and easy, provides a quality finish with no unsightly brush
marks. The Spray Station can spray many types of paint, such as stains,
varnishes, emulsion, glazes, wood treatments and many more.
TROUBLE SHOOTING
IF A PROBLEM OCCURS ALWAYS SWITCH THE UNIT OFF IMMEDIATELY.
PROBLEM CAUSE ACTION
Unit fails to boil. Safety cut-out has Refill boiler making sure to cover the element;
operated. allow unit to cool for 20 mins then re-try.
Fuse has blown in lead. Replace with a 13 amp fuse only.
Power cord extension Extension cables must be rated at at least 10
being used. amps and fully unwound. A lower rating will trip out.
Element burnt out due The element cannot be replaced, you can buy a
to tilting of unit in use or a replacement boiler from our Service Department.
chemical used in boiler.
Unit leaks from Pressure Dirty seal. Unplug the unit and allow to cool. Clean seal and
Relief valve. surface it sits on.
Blockage/kink in hose. Allow unit to cool then remove hose and check for
blockages.
Blockage in inlet of tool. When unit is cool check for obstruction in inlet.
IF YOU REQUIRE FURTHER ASSISTANCE PLEASE CONTACT OUR HELPLINE ON
Tel: 01483 454666 Fax: 01483 454548 email: enquiries@earlex.co.uk
Opening Hours: Monday - Friday 08:30 - 18:00 (Except Bank Holidays)