Assembly
Ensure hose is straight when inserting wand.
The use of an extension cord is not recommended.
Store the machine indoors. Put the vacuum cleaner away after use with the cord
coiled safely, to prevent tripping accidents.
1 Brushbar control
The brushbar will re-set to "ON" each time you start the machine and put it in
the cleaning position.
To turn the brushbar off, turn the machine on and press the brushbar
on/off button.
The brushbar will automatically stop if it becomes obstructed.
If the brushbar stops during use, please refer to the brush bar reset section.
2 Usage and carrying
Caution Please note: this machine is intended for domestic use only. Fine dust
such as plaster dust or flour should only be vacuumed in very small amounts.
Do not press the cyclone release button while carrying the machine or it could
fall and cause injury.
Ensure the cyclone is secured to the machine.
Do not shake the machine while carrying or it could fall and cause injury.
When finished cleaning, push machine into an upright position to drop
stabilizing wheels.
Ensure wheels are fully locked in place before releasing the cleaner.
Consult your flooring manufacturer's recommended instructions before
vacuuming and caring for your flooring, rugs, and carpets. Some carpets will fuzz
if a rotating brushbar is used when vacuuming. If this happens, we recommend
vacuuming in hard floors mode and consulting with your flooring manufacturer.
3 Wand release/using tools
Ensure machine is in upright position before using tools.
To protect your floors, the brushbar will not rotate when the machine is in an
upright position.
Ensure hair and loose clothing are kept clear of wand cap when machine is
switched on.
Ensure wand cap is closed, unless using with tools.
Powerful suction can cause the hose to ‘pull back’ - please take care when
cleaning stairs.
To avoid personal injury and to prevent the machine from falling when cleaning
stairs, always place it at the bottom of the stairs.
Do not use your vacuum cleaner outdoors or on wet surfaces. Vacuum may be
used inside a garage only with the Model 08909 Dyson Car Cleaning Kit
accessories. If used in a garage, care should be taken to wipe the soleplate and
wheels with a dry cloth after vacuuming to clean off any sand, dirt, or pebbles
which could damage delicate floors.
4 Emptying the Clear bin
TM
Empty as soon as the dirt reaches the level of the max mark – do not overfill.
Turn power off and unplug before emptying the bin. Failure to do so could result
in electric shock or personal injury.
Do not use the machine without the clear bin in place.
The British Allergy Foundation is a UK national charity with the aim of improving
awareness, prevention and treatment of allergies.
The British Allergy Foundation Seal of Approval is a UK registered trademark.
5 Cleaning the Clear bin
TM
Clean the shroud with a cloth or dry brush.
Rinse the Clear bin
TM
with cold water only. Ensure bin is dry before replacing.
Do not use detergents, polishes or air fresheners to clean the Clear bin
TM
.
Do not immerse the whole cyclone in water.
Do not put the Clear bin
TM
in a dishwasher.
Ensure Clear bin
TM
is completely dry before replacing.
6 Clearing blockages/brushbar
Please note: clearing blockages is not covered by your machine’s
limited warranty.
Turn power off and unplug before checking for blockages. Failure to do so could
result in electric shock or personal injury.
If any part of your machine becomes blocked, it may overheat and then
automatically shut off. Unplug machine and leave to cool down. Clear blockage
before restarting.
Please ensure you check your brushbar regularly for any build up of hair or
other blockages.
Please ensure machine is upright before removing hose or airway inspection parts.
Beware of sharp objects when clearing blockages.
Refit all parts of the machine securely before using.
7 Washing filter
Check your filter regularly and wash at least every 3-6 months according to
instructions to maintain performance.
Turn power off and unplug before washing the filter. Failure to do so could result
in electric shock or personal injury.
The filter may require more frequent washing if vacuuming fine dust.
Do not use detergent to clean filter.
Do not put the filter in the dishwasher, washing machine, tumble dryer,
microwave or near an open flame.
SAVE THESE INSTRUCTIONS
THIS APPLIANCE IS INTENDED FOR HOUSEHOLD USE ONLY
USER GUIDEIMPORTANT SAFETY INFORMATION
Take care to ensure objects or body parts are not inserted into the cleaner head.
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety. Children should
be supervised to ensure that they do not play with the appliance.
The plug must be removed from the socket outlet before cleaning or
maintaining the appliance.
Check to ensure your electricity supply corresponds to that shown on the
rating plate, which can be found behind the bin. The machine must only be
used as rated.
If the supply cable or the cleaner is damaged, disconnect from the socket
immediately. The cable must be replaced by Dyson or our appointed agent
to avoid a hazard.
Do not use the cleaner if the cable or plug are damaged or if the cleaner
has been damaged, dropped or has come in to contact with water or any
other liquid. In these cases, contact Dyson Customer Care.
When vacuuming, certain carpets may generate small static charges in
the Clear bin
TM
. These are entirely harmless and not associated with the
power supply.
Do not use the cleaner if any parts appear to be faulty, missing or damaged.
Do not carry out any maintenance work other than that shown in this manual
or advised by Dyson Customer Care, and do not put anything into the
openings or moving parts of the machine.
Only use parts recommended by Dyson; failure to do so could invalidate
your guarantee.
If you have a query about your Dyson, call Dyson Customer Care with your
serial number, which can be found on the rating plate behind the bin.
European conformity information
A sample of this product has been tested and found to be in conformity with
the following European Directives: 73/23/EEC Low voltage (safety) Directive,
93/68/EEC CE Marking Directive and 2004/108/EC EMC Directive.
Product information
Product weight: 6.7kg, Voltage: 230-240V, Maximum Power: 1200 WA. Small
details may vary from those shown.
Do not pull on the cable
Do not use near naked flame
Do not use near heat sources
Do not run over the cable
Do not pick up water or liquids
Do not pick up burning objects
Do not use above you on the stairs
Do not put your hands near the brushbar when the
cleaner is in use
This product is protected by the following intellectual property rights:
Patent/Patent Application numbers:
US 2004/0128789, JP 2004-537336, EP 1361812, AU 744408, EP1119282,
JP 2002-527132, US 6,519,807, AU 2002231965, EP 1361813,
JP 2002-567126, US 2004-0068829, AU 744362, EP 1121043,
JP 2002-527131, US 6,572,078, GB 0326102.1, AU 2002226556,
EP 1370172, JP 2004-528876, US 2004-0074213 , AU 2002225207,
EP 1361814, JP 2004-520137, AU 2001240894, EP 1268076,
JP 2003-528704, US 6,835,222, AU 2002-225232, EP 1361815,
JP 2004-520139, US 6,974,488, AU 637 272, EP 0636338, JP 1948 863,
US 5,078,761, AU2003-283159, EP 1526797, JP 2005-534442,
US 2005-0223516, AU 2003-283161, EP1526798, JP 2006-50 3608,
US 10/523246, GB 2422094
16481_DC18_SA_OP_Manual.qxd 12/6/06 5:38 PM Page 4