Ducane (HVAC) Horizontal 80 Furnace User Manual


 
NATURAL TO LP GAS CONVERSION KIT 20490601
NATURAL TO LP GAS CONVERSION KIT
20269401
HIGH ALTITUDE
DUCANE BLOWER EXTERNAL STATIC (in. w. c.)
MODEL NUMBER SPEED 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
B050A3B LOW 615 605 595 580 555 525 490 445 395 340
(10 X 6 WHEEL) MED 925 940 945 935 915 890 850 800 735 665
(1/3 HP MOTOR) HIGH 1570 1550 1515 1470 1415 1340 1255 1160 1050 925
B075A3B LOW 1005 975 940 905 870 835 795 750 705 665
(10 X 6 WHEEL) MED 1405 1340 1280 1215 1150 1085 1015 945 870 795
(1/3 HP MOTOR) HIGH 1755 1695 1635 1560 1475 1385 1285 1170 1045 915
B075A4B LOW 1415 1405 1390 1355 1315 1255 1190 1105 1015 905
(10 X 6 WHEEL) MED 1745 1695 1635 1565 1485 1405 1310 1205 1095 980
(1/2 HP MOTOR) HIGH 1915 1845 1765 1680 1590 1495 1390 1285 1165 1045
B100A4B LOW 1260 1235 1205 1175 1140 1105 1065 1025 985 940
(12 X 9 WHEEL) MED 1470 1465 1465 1455 1435 1410 1375 1335 1295 1240
(1/2 HP MOTOR) HIGH 1845 1825 1795 1755 1715 1665 1610 1550 1485 1410
B100A5B LOW 1380 1365 1340 1305 1265 1215 1160 1090 1015 925
(12 X 9 WHEEL) MED 1795 1780 1755 1720 1670 1610 1540 1455 1360 1255
(3/4 HP MOTOR) HIGH 2385 2330 2265 2195 2105 2015 1910 1795 1670 1535
B125A5B LOW 1420 1390 1355 1315 1270 1220 1165 1110 1045 980
(12 X 12 WHEEL) MED 1815 1770 1720 1665 1610 1550 1490 1425 1356 1285
(3/4 HP MOTOR) HIGH 2215 2175 2130 2080 2020 1960 1890 1815 1735 1650
AIR FLOW DATA
NOTES: 1) Air flow values in cubic feet per minute (CFM), rounded to nearest five (5) CFM
2) Data taken without filters or AC evaporator coil in place
NATURAL TO LP GAS CONVERSION KIT 20490601
NATURAL TO LP GAS CONVERSION KIT
20269401
HIGH ALTITUDE
ACCESSORIES
FPBB050A3B FPBB075A3B FPBB075A4B
FPBB100A4B FPBB100A5B FPBB125A5B