4HP13 Split System Heat Pump
seer
13
Outdoor
Model
Indoor
Model
Outdoor Ambient Temperature
65 60 55 50 47 45 40 35 30 25 20 17 15 10
4HP13*18P-
1A
RBCS2M18C
*****P
Btuh 21,500 20,200 18,700 17,500 16,800 16,300 15,400 14,300 13,100 12,300 10,900 10,500 9,800 8,700
Kw 1.58 1.55 1.53 1.50 1.49 1.480 1.47 1.46 1.44 1.43 1.42 1.41 1.40 1.39
COP 3.98 3.82 3.58 3.42 3.30 3.22 3.06 2.86 2.66 2.52 2.24 2.18 2.04 1.84
4HP13*24P-
1A
RBCS2M24C
*****P
Btuh 24,100 23,500 22,800 22,000 21,400 20,800 19,200 17600 16200 14700 13000 11800 11200 9200
Kw 1.94 1.92 1.90 1.88 1.87 1.84 1.76 1.73 1.69 1.66 1.62 1.60 1.59 1.55
COP 3.64 3.59 3.52 3.44 3.34 3.32 3.20 2.98 2.80 2.60 2.34 2.18 2.06 1.74
4HP13*30P-
1A
RBCS2M30C
*****P
Btuh 30,200 29,500 28,500 27,600 27,000 25,700 23,500 22,300 20,600 18,400 16,500 15,400 14,700 12,100
Kw 2.47 2.43 2.40 2.38 2.37 2.31 2.25 2.21 2.16 2.11 2.04 2.01 2.00 1.93
COP 3.58 3.56 3.48 3.40 3.34 3.26 3.06 2.96 2.80 2.56 2.38 2.26 2.14 1.84
4HP13*36P-
1A
RBCS2M36C
*****P
Btuh 37,600 36,300 35,200 34,000 33,000 31,300 29,300 27,500 25,300 22,800 20,500 19,000 17,900 15,100
Kw 3.03 2.95 2.90 2.87 2.85 2.76 2.70 2.64 2.59 2.54 2.49 2.45 2.45 2.41
COP 3.64 3.60 3.56 3.46 3.40 3.32 3.18 3.04 2.86 2.62 2.40 2.26 2.14 1.84
4HP13*42P-
1A
RBCS2M42C
*****P
Btuh 43,500 42,400 41,000 39,200 38,500 36,100 32,800 30,900 28,300 25,200 22,400 21,200 18,700 13,300
Kw 3.54 3.47 3.41 3.32 3.30 3.23 3.11 3.04 2.88 2.70 2.49 2.39 2.28 2.00
COP 3.60 3.58 3.52 3.46 3.42 3.28 3.08 2.98 2.88 2.74 2.64 2.60 2.40 1.94
4HP13*48P-
1A
RBCS2M60C
*****P
Btuh 51,800 49,100 46,200 44,200 43,500 41,900 41,300 37,400 34,900 32,500 29,700 27,400 26,600 24,200
Kw 4.56 4.35 4.14 4.00 3.98 3.87 3.83 3.64 3.52 3.44 3.31 3.23 3.22 3.13
COP 3.32 3.30 3.26 3.24 3.20 3.18 3.16 3.00 2.90 2.76 2.62 2.50 2.42 2.26
4HP13*60P-
1A
RBCS2M60C
*****P
Btuh 58,700 56,300 54,200 52,900 52,000 49,600 46,600 42,400 39,300 36,100 32,600 30,400 29,000 25,500
Kw 4.34 4.19 4.14 4.10 4.07 4.03 3.96 3.82 3.72 3.63 3.53 3.46 3.41 3.31
COP 3.96 3.94 3.84 3.78 3.74 3.60 3.44 3.24 3.10 2.92 2.70 2.58 2.48 2.26
Heating Performance with Extended Ratings
* = B, L
The information below is for nominal CFM and 70° indoor dry bulb.