Ducane (HVAC) 2HP14 Heat Pump User Manual


 
2 HP 14 B 36 P - 1 A
Model Number Guide
Refrigerant – 2 = R22
AC = Condenser
HP = Heat Pump
14 - 14 SEER Nominal
Family / Coil Protection
B = Non-Louvered
L = Louvered
A = Service Level
Revision Code
Voltage
P - 208-230v/60hz
Single Phase
Nominal Capacity
36 - 36,000 Btuh
Sound Ratings
Model Sound Rating (dBa) Weight
2HP14(B,L)18P-1* 78 162
2HP14(B,L)24P-1* 79 175
2HP14(B,L)30P-1* 79 187
2HP14(B,L)36P-1* 79 195
2HP14(B,L)42P-1* 78 222
2HP14(B,L)48P-1* 78 224
2HP14(B,L)60P-1* 80 275
2HP14 Split System Enhanced Heat Pump
seer
14
Voltage/Phase/Hz
Compressor Fan Motor
Voltage/ Voltage
Min.
Maximum
Refrig.*
Model
Hz/Phase Range
Rated Locked Condenser Rated
Nom.
Circuit
Over-
Charge
Load
Rotor Fan Load
RPM
Ampacity
Current
(oz.)
(Amps)
(Amps) HP (Amps)
Device
2HP14*18P-1* 208-230/1/60 197 - 253 8.3 41 1/10 0.7 1075 11.1 20 139
2HP14*24P-1* 208-230/1/60 197 - 253 10.3 56 1/10 0.7 1075 14.6 25 131
2HP14*30P-1* 208-230/1/60 197 - 253 12.2 61 1/5 0.8 1075 16.0 25 160
2HP14*36P-1* 208-230/1/60 197 - 253 13.5 73 1/5 0.8 1075 18.4 30 177
2HP14*42P-1* 208-230/1/60 197 - 253 16.5 95 1/4 1.4 1075 22.2 35 188
2HP14*48P-1* 208-230/1/60 197 - 253 18.0 104 1/4 1.4 1075 23.7 40 273
2HP14*60P-1* 208-230/1/60 197 - 253 19.2 137 1/3 2.0 1075 26.0 40 252
*15 feet of line sets included.