Ducane B Air Conditioner User Manual


 
2AC14SplitSystemAirConditioner
14
2 AC 14 B 36 P - 1 A
ModelNumberGuide
Refrigerant – 2 = R22
AC = Split Condensing
Unit
14 - 14 SEER Nominal
B = Wire Guard
L = Louvered
BC = Wire Guard + 76dBA
LC = Louvered + 76dBA
Minor Revision Code
Major Revision Code
Voltage
P - 208-230v/60hz
Nominal Capacity
36 - 36,000 Btuh
Model
Voltage/ Hz/
Phase
Voltage
Range
Min.
Circuit
Amp.
Maximum
Over
Current
Device
(amps)
Compressor Fan Motor
Refrig.
Charge
(oz.)
:
Weight (lbs.)
Rated
Load
(Amps)
Locked
Rotor
(Amps)
Full Load
Amps
Rated
HP
Nom.
RPM
Wire Guard/
Louvered
2AC14**18P 208-230/60/1 197 - 253 9.7 15 6.9 35 1.1 1/10 1075 106 185
2AC14**24P 208-230/60/1 197 - 253 11.6 20 8.4 39 1.1 1/10 1075 129 201
2AC14**30P 208-230/60/1 197 - 253 15.2 25 11.3 51 1.1 1/5 1075 154 227
2AC14**36P 208-230/60/1 197 - 253 17.2 30 12.9 61 1.1 1/5 1075 165 226
2AC14*42P 208-230/60/1 197 - 253 21.5 35 16.2 82 1.2 1/4 1075 204 262
2AC14*48P 208-230/60/1 197 - 253 22.6 35 17.1 100 1.2 1/4 1075 208 261
2AC14*60P 208-230/60/1 197 - 253 28.8 50 21.4 137 2.0 1/3 1075 264 270
ElectricalandPhysicalData
:
Factory charged for 15 feet of line set. Adjust per Installation Instructions
** = B, L, BC, LC
* = B, L
Dimensions(in.)andSoundRatings
Model
Dimensions
B, L
Sound Rating
(dBa)
BC, LC
Sound Rating
(dBa)
A - width
(in.)
B - depth
(in.)
C - height
(in.)
2AC14**18P 30 30 25.5 80 76
2AC14**24P 30 30 25.5 80 76
2AC14**30P 30 30 33.5 79 76
2AC14**36P 30 30 33.5 80 76
2AC14*42P 30 30 41.5 76 ---
2AC14*48P 30 30 41.5 78 ---
2AC14*60P 30 30 41.5 80 ---
** = B, L, BC, LC
* = B, L