Drolet ULC S627 Stove User Manual


 
10
If you are using a masonry chimney, it is important that it be built in compliance with the specifications of the
Building Code. It must be lined with fire clay bricks, or clay tiles, sealed together with fire cement, or have a
listed solid fuel burning stainless steel liner. Round chimneys are the most efficient.
The interior diameter of the chimney should be identical to the stove's smoke exhaust. A chimney which is
too small may cause draft problems, since it may not have the required volume to properly evacuate the
quantity of smoke resulting from the combustion. A chimney whish is too large may also cause draft
problems. In fact, a large chimney will be harder to warm-up and may not reach high enough temperatures to
create a proper draft effect. Note that it is the chimney which creates the draft effect, not your stove.
Your stove's performance is therefore directly dependent on an adequate draft from your chimney.
The following recommendations may be useful for the installation of your chimney:
Do not connect your stove to a chimney serving another appliance.
The chimney must rise above the roof at least 3' (0.9 mm) from the uppermost point of contact. See
Figure 2.2.
The chimney must exceed any part of the building or other obstruction within a 10' (3.04 m) distance
by a height of at least 2' (0.6 m). See Figure 2.2.
The minimum overall height of the chimney system, measured from the stove top to the exterior
termination cap of the chimney should be at least 12' (3.66m). A chimney which is too short may lack
the “tunnel effect” required to obtain a proper draft.
Installation of an interior chimney is always preferable to an exterior chimney. Chimneys constructed
outside of the home on an exterior wall should be avoided if possible, especially in colder climates.
The gas which circulates into an interior chimney will cool more slowly, thus reducing the build-up
of creosote and the risk of flue fires.
All else being equal, cooler chimneys will have less draft than hotter ones. This problem will be
amplified if the chimney is excessively long. A chimney which is excessively long may be very hard
to warm-up due to its higher volume. A cool chimney may even down draft (reverse flow) due to the
difficulty in heating it up to operating temperature while trying to evacuate the stack gases.
If an exterior chimney is used, the best results will be obtained by using a connector vertically off the
unit to the highest possible point before elbowing off horizontally to the exterior chimney. For
efficiency and safety reasons the stove must not be installed with an insulated chimney connected
directly to the appliance.
Using a fire screen at the extremity of the chimney requires regular inspection in order to insure that it
is not obstructed, thus blocking the draft. It should be cleaned when necessary.