Drolet Adirondack Indoor Fireplace User Manual


 
18
OUTSIDE COMBUSTION AIR
Your DROLET stove is approved to be installed with an outside air intake which is
necessary for a mobile home. This type of installation is also required in air tight houses
and houses with negative pressure problems. You can purchase this option through your
DROLET dealer. Make sure to specify this part number: #AC02080. Installation
instructions are supplied with the air intake kit.
Outside combustion air may be required if:
1. Your stove does not draw steadily, smoke rollout occurs, wood burns poorly, or
back-drafts occur whether or not there is combustion present.
2. Existing fuel-fired equipment in the house, such as fireplaces or other heating
appliances, smell, do not operate properly, suffer smoke roll-out when opened, or
back-drafts occur whether or not there is combustion present.
3. Opening a window slightly on a calm (windless) day alleviates any of the above
symptoms.
4. The house is equipped with a well-sealed vapour barrier and tight fitting windows
and/or has any powered devices that exhaust house air.
5. There is excessive condensation on windows in the winter.
6. A ventilation system is installed in the house.
WARNINGS for use in MOBILE HOMES:
DO NOT INSTALL IN SLEEPING ROOM.
THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL, AND CEILING/ROOF MUST BE
MAINTAINED.
THE STOVE MUST BE ATTACHED TO THE STRUCTURE OF THE MOBILE HOME.
INSTALL IN ACCORDANCE WITH 24 CFR, PART 3280 (HUD).
USE A FACTORY BUILT CHIMNEY THAT COMPLY WITH UL 103 OR ULC S629 STANDARDS;
THEREFORE IT MUST BE A TYPE HT (2100°F).