2020/2220/2520/2210/2510/2200/2500 8 03.27883.100
4.1.4. Combustible material round the fireplace
Within the radiation area of the fireplace
Assure a distance of at least 80 cm between the opening of the fireplace and com-
bustible material. That distance may be reduced to 40 cm if the combustible mate-
rial is sufficiently shielded and well ventilated.
Outside the radiation area of the fireplace
Assure a distance of at least 5 cm between the mantle
built around the fireplace and combustible material. A
small surface contact between combustible material and
the mantle (e.g. wall cladding) is allowed if the mantle of
the fireplace is sufficiently insulated.
A wooden ornamental rafter must not be installed within
the radiation area of the fire. Outside the radiation area,
there must always be a ventilation gap of 1 cm all around
to prevent heat from building up (see picture).
No combustible material must be present within 50 cm from the convection outlet
areas.
4.2. Preparation
Please inspect the fireplace for damage caused during transport immediately after
delivery and notify your distributor in case there are any defects. Do not put the ap-
pliance into operation in the meantime.
In order to avoid damaging the fireplace during installation and to make its handling
easier, it is recommended to remove previously all loose parts (fire-resistant bricks,
grille, ashtray, ...) from the stove. Note the location of those parts while removing
them, so that you have no difficulties in re-assembling the parts later on.
4.2.1. Changing the direction of the door-opening
It is possible to change the direction of the door ope n-
ing. On each side you have already the system.
4.2.2. Removing the clapet
You can remove the clapet and the tige by holding it upward and moving it a little
over the baffle -plate. When you loose the bolt in the topplate you can remove the
baffle plate.
min 1 cm
min 1 cm