Dometic VN 880 Air Conditioner User Manual


 
ENGLISH
Volvo L-5 A/C - Air Distribution System
20
Figure 20. Routing of refrigerant lines.
TESTING THE INSTALLATION
Supply power to the power distribution panel with
either shorepower or generator power. Look at the
display panel and conrm that the display is lit up.
Press the FAN button to activate the fan in manual
mode. Check for airow from all vents. Next, press
the HEAT button and run the SETpoint up sufciently
for the unit to come on in heat mode. The HEATING
LED should illuminate. The air should start warming
up. To conrm heating quicker, manually lower the fan
speed ot the lowest setting.
Next, check the cooling mode. Press the COOL
button, then run the SETpoint down sufciently for the
unit to come on in the cool mode. The COOLING LED
should illuminate. The air should start cooling down.
Check to make sure the condenser fan is running. If
it is cool, it may take a few minutes for the condenser
fan to come on. This is normal. Shut down the unit by
pressing OFF. You are now nished with the installa-
tion.