Dometic Battery--Powered Auxiliary Air Solutions
◆ CARBapproved
◆ Runs on12Vpower frombankof Group31
AGMbatteries
◆ Complies with all anti-idle laws
◆ Suitable for day cabs or sleepers
◆ 7,000 and 10,000 BTUcapacities
•Self-contained package units
•Patented split systems with reusable
precharged refrigerant linesets
◆ Heating options
•1 to 2 KWbuilt-in electric heat
•Interfacewithinstalleddiesel-firedheaters
◆ No special tools required to install
◆ Turnkeypackage includes all components
needed to complete installation
◆ Backed by extensive application engineering
support andnationwide service
◆ Designedand built for over-the-roadconditions
and thoroughly field-tested
Wouldn’t it be great if you could run an air
conditioner in your trucks without idlingthe
engineor crankingupaseparatediesel genera-
tor? Now, thanks to Dometic engineering,
it’s a reality.
Dometic’s battery-powered all-electric sys-
tems run on 12 Volt power fromthe truck’s
batteries. This means no auxiliary diesel genset
or APUis needed. No noise. No exhaust emissions. No fuel
consumption. No maintenance. Nothing but clean, quiet
comfort. And the CARB-compliant Dometic solution meets
the most stringent clean-air laws without any future modifica-
tions.
In addition to the Dometic air conditioning units and associat-
ed ducts, grills and controls, the turnkey systemincludes a
high-performance alternator with external regulator, DC-AC
inverter/charger, Group 31 AGMbatteries and optional shore-
power plug. No special tools are required for systeminstalla-
tion or maintenance.
You can rely on Dometic Environmental Corporation, with its
45+ year heritage in rugged HVAC technology for harsh envi-
ronment applications, for thoroughlyengineered products
designedfor the harshestover-the-road conditions backed by
unmatched factory support and after-sale service.
Visit www.dometictruck.comto getcomplete details on how
to select, specify, operate and maintain a battery-powered
auxiliaryair conditioning system.
SplitSystems
Model CoolCapacity
(BTU)
HeatCapacity Control Height
(in.)
Width
(in.)
Length
(in.)
Weight
(lb.)
Coolamps Heat
amps
Refrigerant
Internal Unit - Evaporator/Heater/Compressor
ECEQ7 7,000 Cooling only Smart digital 11.75 10.25 19.25 53 7.3 n/a R417a
EHCEQ7 7,000 1 KW Smart digital 11.75 10.25 19.25 53 7.3 8.2 R417a
ECEQ10 10,000 Cooling only Smart digital 11.63 11.12 20.19 60 11.8 n/a R417a
EHCEQ10 10,000 7500 BTU
Espar Ready
Smart digital 11.63 11.12 20.19 60 11.8 1.0 R417a
EHCEQ10 10,000 1.5 KW Smart digital 11.63 11.12 20.19 62 11.8 13 R417a
EHCEQ10 10,000 2 KW Smart digital 11.63 11.12 20.19 62 11.8 17 R417a
External Unit - Condenser
ACCD7 7,000 n/a n/a 6.125 11.3125 21.875 10 n/a n/a R417a
ACCE10 10,000 n/a n/a 6.125 12.5 24.5 12 n/a n/a R417a
Self-ContainedUnits
ASCF7 7,000 Cooling only Mechanical 12.5 15.25 21.5 62 8.5 n/a R22
ASCEQ7 7,000 Cooling only Smart digital 11.94 17.75 24 70 8.9 n/a R417a
ASCEQ7 7,000 7500 BTU
Espar ready
Smart digital 11.94 17.75 24 70 8.9 1.8 R417a
ASCEQ7 7,000 1 KW Smart digital 11.94 17.75 24 71 8.9 9.5 R417a
ASCEQ7 7,000 1.5 KW Smart digital 11.94 17.75 24 71 8.9 13.4 R417a
ASCDQ10 10,000 Cooling only Smart digital 12.5 20.87 28.25 91 12.9 n/a R22
ASCDQ10 10,000 1.5 KW Smart digital 12.5 20.87 28.25 92 12.9 13.9 R22
ASCDQ10 10,000 2 KW Smart digital 12.5 20.87 28.25 92 12.9 18.2 R22
Split unit
Control
Inverter
Alternator
Self-contained
unit