Dirt Devil CV2200 Vacuum Cleaner User Manual


 
Dirt Devil
®
Built - In Central Vacuum Systems
OPERATING INSTRUCTIONS
Dirt Devil
®
Filtered Cyclonic
MODELS:
CV1800, CV2200 & CV2600
General Information
Do Not Store Objects on top of the
power unit. This will block the motor
cooling ventilation. Restricting the
cooling airflow may shorten the
motor life.
The central vacuum is designed to
vacuum ordinary household dirt and
dust. The system is designed for dry
pickup. A Wetvac accessory is needed
if the system will be used for liquid
pickup.
The central vacuum system is a
network of inlet valves, 2” PVC
tubing, and low voltage wiring
installed in the walls of your home.
To operate the system, simply plug
the hose into an inlet valve, attach
the cleaning tool to the curved hose
end and begin vacuuming. The dirt
is transported through the in-wall
tube system back to the dirt canister
(located on the power unit).
Caution: Do not allow the motor to
remain turned on, unless a hose is
connected or an inlet valve is open. If air
is not permitted to pass through the fan
blades, damage may occur to the motor.
Operating Instructions
Using the Central Vacuum System is
easy. Simply raise the inlet valve lid,
insert the hose end and attach the
desired cleaning tool to the
hose wand. The Power Unit is activated
when the hose is inserted into the
valve.
Emptying the Dirt
Canister & Replacing
The Filter Cartridge
The dirt canister – where the
vacuumed dirt is deposited – is the
removable lower portion of the
power unit. The canister needs to
be removed and emptied when it is
1/2 - 2/3 full. The filter cartridge
should be replaced once a year.
When the dirt canister is removed
the Cyclonic Cone will be visible.
The cone is designed to stay
attached to the body of the power
unit when the dirt canister is
removed. The cone is removable to
allow access to the replaceable
pleated filter. To replace the cone,
follow the steps listed under
replacing the filter.
Follow these steps to empty the dirt
canister (refer to Illustration #1)
Make sure the Power Unit is OFF.
1) Disengage the canister latches
located on opposite sides of the
power unit.
2) Remove the dirt canister.
3) Dispose of canister contents in
trash receptacle.
4) Raise the empty dirt canister to the
proper location under the power
unit and engage the latches.
5) Be certain the dirt canister and
the cyclonic cone seal are
“seated” properly to the body of
the unit.
Follow these steps to replace the
filter cartridge
(refer to Illustration #2)
Make sure the Power Unit is OFF.
1) Unlatch and remove the Dirt
Canister.
2) Remove the cyclonic cone by
pulling down on it. Place cone
in dirt canister.
3) Remove the pleated filter by
turning the filter latch 90˚ (counter-
clockwise) to disengage the filter.
(The filter latch is located at the
bottom of the pleated filter)
4) Insert new pleated filter (p/n
8106-01) and engage filter latch
(by rotating it 90˚ clockwise until
you feel it snap in place).
5) Raise the dirt canister (with cone
inside) to the proper location
under the power unit and engage
the latches.
6) Be certain the dirt canister and
cyclonic cone seal are “seated”
properly to the body of the unit.
ILLUS. #1
Filter
Cartridge
Filter Latch
(turn 90° to
disengage filter)
Dirt Canister
Cyclonic
Cone Seal
Cyclonic Cone
ILLUS. #2
General Power Unit
Maintenance
The simple care and maintenance
instructions included here will
help ensure trouble-free use of the
central vacuum system.
Do not place objects on top of the
power unit. The motor could
overheat.
Do not allow the motor to remain
“on” unless a hose is connected or
an inlet valve is open. If airflow is
not permitted to flow through fan
blades, motor damage may occur.
Do not operate without a filter in
place.
Empty the dirt canister when it is
1/2 - 2/3 full.
Change the filter cartridge once a
year.
The power unit does not require
any lubrication.
The exterior of the power unit can
be wiped with a clean, dry cloth.
Do not use liquid cleaners or water
as an electrical shock may occur.
For additional service contact a
qualified service person.
Troubleshooting
the System
Motor Fails to Turn On:
Check the main fuse or circuit
breaker at the main power supply
panel of your home. Reset breaker
or replace fuses if necessary.
Check the Power unit reset button
located above the power cord.
Pressing the button should restore
operation.
If the circuit protector continues to
trip off after a short period of time,
the motor brushes may be worn
out. Call a qualified service person
for service.
Loss of Vacuum
If the system shows a loss of vacuum
power, check the following:
The dirt receptacle and filter may
need cleaned – follow instructions
in this guide.
The hose may be clogged – To
check if there is an obstruction,
unplug the hose and insert an
object that is smaller then the
diameter of the hose (A butter knife
works well). Pass the object
completely through the hose, if it
stops that will indicate where the
obstruction is located. A dry garden
hose can be inserted into the hose
to help push obstruction through.
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USING THIS VACUUM SYSTEM
WARNING
To reduce the risk of fire, electric shock or injury:
When using an electrical appliance, basic precautions should
always be followed, including the following:
Unplug and disconnect power
before servicing.
Do not use on wet surfaces.
Do not allow to be used as a toy.
Close attention is necessary
when used by or near children.
Use only as described in this
manual. Use only manufacturer's
recommended attachments.
Do not use with damaged cord
or plug. If appliance is not
working as it should, has been
dropped, damaged, left outdoors,
or dropped into water, return it
to a service center.
Do not pull or carry by cord, use
cord as a handle, close a door on
cord, or pull cord around sharp
edges or corners. Do not run
appliance over cord. Keep cord
away from heated surfaces.
Do not unplug by pulling on
cord. To unplug, grasp the plug,
not the cord.
Do not handle system or appliance
with wet hands.
Do not put any object into open-
ings. Do not use with any open-
ing blocked. Keep openings free of
dust, lint, hair, and anything that
may reduce air flow.
•Keep hair, loose clothing, fingers,
and all parts of body away from
openings and moving parts.
Do not pick up anything that is
burning or smoking, such as
cigarettes, matches, or hot ashes.
Connect to a properly grounded
outlet. See grounding instructions.
•Turn off all controls before
unplugging.
Use extra care when cleaning
on stairs.
Do not use to pick up flammable
or combustible liquids such as
gasoline or use in areas where
they may be present.
Do not place or store anything
on top of power unit – over-
heating of motor could occur.
Do not use without filter in place.
SAVE THESE INSTRUCTIONS
INTENDED FOR HOUSEHOLD AND LIGHT COMMERCIAL USE.
IMPORTANT INFORMATION FOR CENTRAL VAC OWNERS
Dirt Devil
®
Models CV1800, CV2200 & CV2600
OPERATING INSTRUCTIONS
Do not vent into a wall, a ceiling, or concealed space of a building or structure.
GROUNDING METHOD
FIG. A
GROUNDING
INSTRUCTIONS
This appliance must be grounded. If it
should malfunction or break down,
grounding provides a path of least
resistance for electric current to reduce the
risk of electric shock. This appliance is
equipped with a cord having an equipment
grounding conductor and grounding plug.
The plug must be plugged into an
appropriate outlet that is properly installed
and grounded in accordance with all local
codes and ordinances.
WARNING
Improper connection of the equipment-
grounding conductor can result in a risk of
electric shock. Check with a qualified
electrician or service person if you are in
doubt as to whether the outlet is properly
grounded. Do not modify the plug
provided with the appliance - if it will not
fit the outlet, have a proper outlet installed
by a qualified electrician.
The CV1800, CV2200 & CV2600
appliances are for use on a nominal 120
volt circuit and has a grounding plug that
looks like the plug illustrated in Fig.A.
Make sure that the appliance is connected
to an outlet having the same configuration
as the plug. No adapter should be used
with this appliance.
Connect to a properly grounded outlet only.
®
ELECTRIC SHOCK
COULD OCCUR IF
USED ON WET
SURFACES.
CAUTION:
DO NOT USE ON WET
RUG OR FLOOR.
US LISTED
WARNING:
CV1800, CV2200 & CV2600 Warranty
All Permanently installed components of the Dirt Devil
®
Built-In Central Vacuum System are
warranted to be free from defects in material and workmanship under normal use and care as
long as the original consumer purchaser owns the home of original installation or until the power
unit is removed from its original installation, whichever occurs first.
In the event of a defect in permanently installed components of the Dirt Devil
®
System, an
authorized dealer should be contacted. Repaired or replacement parts (at our option) will be
provided to you for any items under warranty. Filter cartridges are not covered under warranty
and should be replaced yearly.
Attachments
Dirt Devil
®
cleaning attachments including: turbine power brushes, non-electric hoses, wands,
tools and tool caddies are warranted to be free from defects in material and workmanship under
normal use and care for three (3) years from original date of consumer purchase. Electric power
brushes and hoses, are warranted to be free from defects in material and workmanship under
normal use and care for one (1) year from original date of consumer purchase. In the event of a
defect in a Dirt Devil
®
attachment, a repaired or replacement (at our option) part will be provided
to you for any item(s) under warranty. There is no warranty for consumable items such as light
bulbs, belts and beater brushes.
Limitations of Warranty
The lifetime warranty begins on the date of the original purchase of the unit. This warranty
specifically excludes and there is no warranty on original or replacement filter cartridges and
further excludes any damage due to shipping and handling or damage due to installation, or faulty
installation.
In order to obtain coverage under this warranty, an owner must provide proof of purchase or have
registered the Dirt Devil
®
Central Vacuum Power Unit at 1-800-822-8356 or online at
www.cvacregistration.com, or by completing and mailing the warranty registration card. In
addition, to recover under this warranty, an owner must have provided normal care and mainte-
nance for the unit including, but not limited to, replacing the filter cartridge as needed and
recommended by the Instruction Manual.
THIS WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY FOR THIS PRODUCT. ALL OTHER
WARRANTIES INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY OR WARRANTIES OF
FITNESS FOR A PARTICULAR PURPOSE ARE SPECIFICALLY EXCLUDED. THIS WARRANTY COVERS
ONLY THE LIABILITY AND RESPONSIBILITY DESCRIBED HEREIN, WHICH IS REPAIR OR REPLACE-
MENT, AND THERE IS NO LIABILITY FOR ANY CONSEQUENTIAL, INCIDENTAL OR SPECIAL
DAMAGES ARISING FROM THE USE OF THIS PRODUCT OR THE FAILURE OF THIS PRODUCT
.
H-P Products, Inc. • 512 W. Gorgas Street • Louisville, OH 44641 • 1-800-822-8356