Dimplex (SP9) SP920 Indoor Fireplace User Manual


 
Wall Fires -
Models: SP420, SP520 & SP920
IMPORTANT: THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
Important Safety Advice
When using electrical appliances, basic precautions
should be followed to reduce the risk of fire, electric
shock, and injury to persons, including the following:
If the appliance is damaged, check immediately with
the supplier before installation and operation.
Do not use this heater in the immediate surroundings
of a bath, shower or swimming pool.
Do not use outdoors.
Do not cover or obstruct the heater in any way.
Overheating will result if it is accidentally covered.
In the event of a fault unplug the heater.
Unplug the heater when not required for long periods.
The supply cord is recommended to be placed on the
right hand side of the heater. The heater can also be
HARD wired - this is recommended if the heater is
recessed - see ‘Recessed Installation’.
This appliance is not intended for use by children or
other persons without assistance or supervision if their
physical, sensory or mental capabilities prevent them
from using it safely. Children should be supervised to
ensure that they do not play with the appliance.
If the supply cord is damaged it must be replaced by
the manufacturer or service agent or similarly qualified
person in order to avoid a hazard.
Electrical
WARNING – THIS APPLIANCE MUST BE EARTHED
This heater must be used on an AC ~ supply only and the
voltage marked on the heater must correspond to the supply
voltage.
Do not switch the appliance on until properly installed. Please
read all the safety warnings and operating instructions.
General
Unpack the heater carefully and retain the packaging for
possible future use, in the event of moving or returning the
fire to your supplier.
Contents of Carton
Heater.
Wall fixing bracket.
Fixing screws and wall plugs.
Remote control and batteries
(AAA’s type).
Spare bulb.
Do not connect the heater to an electricity supply until it is
installed on a wall correctly - see ‘Installation’.
SP420 & SP920 - When in operation there is a 300 watt heat
output from the fuel effect, and an additional 120 watt output
when the heated glass panel is in operation.
SP520 - When in operation there is a 300 watt heat output
from the fuel effect, and an additional 200 watt output when
the heated glass panel is in operation.
The heater can be used remotely or manually - see ‘Operation’.
General features of remote control are:
Activate/Deactivate heated glass panel.
The illumination of fuel effect can be increased or
decreased.
Please note: Used in an environment where background
noise is very low, it may be possible to hear the motor which
operates the flame effect. This is normal and should not be
a cause for concern.
Installation
Do not connect appliance until properly fixed to the wall
and the Instruction leaflet is read fully.
The minimum distances must be observed.
For installation of the appliance, care must be taken not to
damage concealed cables.
Please be careful while drilling the holes.
This model is designed to be permanently fixed to a wall at a
minimum height of 300mm. The wall bracket must be fitted
horizontally and the cable routed to the bottom right of the
heater as in Fig. 1.
A height of 600mm from bottom of heater to floor is
recommended for optimum viewing of fuel bed (see Fig. 2 for
recommended fixing dimensions).
For optimum viewing mark the top four screw fixing positions
on wall in accordance with the recommended fixing dimensions
- see Fig. 2. Drill holes with a 6mm drill bit.
Fix the wall bracket using the plugs and screws provided -
see Fig. 3.
Carefully lift the heater up ensuring that the top rear ledge of
heater engages the wall bracket and is sitting centrally
positioned. - see Fig. 4 (b).
Rotate the bottom fixing bracket down. - see Fig. 4 (c).
Gently bring the heater level with the wall. - see Fig. 4 (d).
Mark the bottom hole position (see Fig. 5), remove the heater
ensuring that the bottom fixing bracket is rotated up.
Drill and fit wall plug.
Refit the heater to the wall fixing bracket (i.e. follow steps as
in Fig. 4 a, b, c and d) and rotate the bottom fixing bracket
down again and use the screw provided to permanently fix
the heater in place.
The heater should not be connected until the instruction leaflet
is read fully.
Recessed Installation
Please note that this appliance can also be wall-mounted so
that it is recessed. This can be installed in a large fireplace
opening or a purpose built wall. See Table 1 for size of recess
required and hole fixing dimensions and Fig. 5a. This fireplace
insert does NOT require venting.
In order to ensure it’s future safety in use, it is essential
that this fire is securely fixed to the wall.
IT IS IMPORTANT THAT THE FIXING DEVICE CHOSEN IS
APPROPRIATE TO THE WALL MATERIAL TO WHICH THE
FIRE IS BEING FIXED. SOME MODERN INTERNAL
BUILDING MATERIALS ARE VERY LOW DENSITY BLOCK
AND REQUIRE SPECIALIZED FIXING DEVICES TO
PROVIDE A SAFE,SECURE INSTALLATION.
The installation of this fire should be carried out by a competent
person. If in doubt please consult your local builder.