Dimplex 430 RCE/B Electric Heater User Manual


 
2
4
5
4
1
3
2
Operation
When you are certain that you have completed the installation, plug in and switch on at the wall socket.
Fig. 1
Controls - see Fig. 1
Fuel effect
The fuel effect will be lit all the time that the heater is connected to
the power supply, even if the heat selector switches are in the OFF
position. The flicker rotors should begin to rotate after a minute
or so.
The lamps will go out only when the heater is switched off at the
wall socket or unplugged.
Radiant elements
You have a choice of low heat (two elements, 1332W) or high heat
(three elements, 1998W). Both settings have electronic
temperature control - see below.
A switch is set to ON when the red dot is visible.
Low heat setting
Press switch 1 to ON. Two elements will glow and, when the
temperature selected on the electronic control dial 4 is reached,
one of the elements will automatically turn off, switching back on if
the temperature falls.
See also Electronic economiser temperature control below.
High heat setting
Set switches 1 and 2 to ON. All three elements will glow and, when
the temperature selected on the electronic control dial 4 is
reached, two of the elements will automatically turn off, switching
back on if the temperature falls.
The fire can be returned to low heat setting by pressing switch 2 to
OFF.
See also Electronic economiser temperature control below.
Convector heater
The 700 watt convector heater can be used by itself for
background heating, or in conjunction with the radiant elements for
extra heat.
The convector output is through the vent in the canopy. This vent
must never be covered or obstructed.
Press switch 3 to the ON position. Warm air will now come through
the vent in the canopy until the temperature selected on the
electronic control dial 4 is reached. The convector heater will then
turn off automatically, switching back on if the temperature falls.
See also Electronic economiser temperature control below.
Electronic economiser temperature control
This sensitive output control 4 will switch the radiant and convector
heater elements ON and OFF to accurately maintain the level of
comfort that you have selected.
Select the heat required - convector and/or low or high radiant
setting - then turn the control dial to 7; when the room reaches a
comfortable level of warmth, turn the dial down until the
electronically controlled elements switch off. The control dial
should be left at this setting; the electronic control will then switch
the elements ON and OFF as needed to maintain your chosen
comfort level.