Dimplex LI 11TER+ Heat Pump User Manual


 
www.dimplex.de E-9
English
11
11 Device Information
1 Type and order code
LI 11TER+ LI 16TER+
2Design
2.1 Model Reversible Reversible
2.2 Degree of protection according to EN 60 529 for compact devices
and heating components
IP 21 IP 21
2.3 Installation Location Indoors Indoors
3 Performance data
3.1 Operating temperature limits:
Heating water flow/return flow
1
°C / °C
1. See operating limits diagram
Up to 58 / above 18 Up to 58 / above 18
Cooling, flow °C +7 to +20 +7 to +20
Air (heating) °C -25 to +35 -25 to +35
Air (cooling) °C +15 to +40 +15 to +40
3.2 Temperature spread of heating water at A7 / W35 9.7 5.0 .9..3 5..0
3.3 Heat output / COP at A-7 / W35
2
kW / ---
2. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, other parameters, such as, in particular, the defrosting
capacity, the bivalence point and regulation, should also be taken into consideration. The specified values, e.g. A2 / W55, have the following meaning: 2 °C external air temperature
and 55 °C heating water flow temperature.
7.1 / 2.9 6.6 / 2.7 10.6 / 3.0 10.5 / 2.9
at A-7 / W45
2
kW / ---
6.4 / 2.3 9.9 / 2.5
at A2 / W35
2
kW / ---
8.8 / 3.2 8.8 / 3.1 12.8 / 3.4 12.7 / 3.2
at A7 / W35
2
kW / ---
11.3 / 3.8 11.3 / 3.6 15.1 / 3.8 14.9 / 3.6
at A7 / W45
2
kW / ---
9.6 / 3.1 14.7 / 3.3
at A10 / W35
2
kW / ---
12.2 / 4.1 12.1 / 3.9 16.7 / 4.1 16.6 / 3.9
3.4 Temperature spread of cooling water at A35 / W7 6.5 5.0 6.6 5.0
3.5 Cooling capacity / COP at A27 / W7 kW / --- 8.8 / 2.8 8.8 / 2.8 12.6 / 2.6 12.5 / 2.6
at A27 / W18 kW / --- 10.9 / 3.3 10.8 / 3.2 16.4 / 2.8 16.4 / 2.8
at A35 / W7 kW / --- 7.6 / 2.1 7.5 / 2.1 10.7 / 2.0 10.6 / 2.0
at A35 / W18 kW / --- 9.5 / 2.5 9.5 / 2.5 14.3 / 2.3 14.3 / 2.2
3.6 Sound power level dB(A) 55 / 61 57 / 62
3.7 Sound pressure level at a distance of 1 m (indoors) dB(A) 50 52
3.8 Heating water flow with an internal pressure differential of m³/h / Pa 1.0 / 3000 1.9 / 10900 1.4 / 4500 2.6 / 14600
3.9 Cooling water flow with an internal pressure differential of m³/h / Pa 1.0 / 3000 1.3 / 5900 1.4 / 4500 1.8 / 7000
3.10 Air flow rate with an external static pressure differentia m³/h / Pa 4200 / 0 5200 / 0
m³/h / Pa 2500 / 25 4000 / 25
3.11 Refrigerant; total filling weight type / kg R404A / 5.1 R404A / 5.7
4 Dimensions, connections and weight
4.1 Device dimensions H x W x L cm 136 x 75 x 88 157 x 75 x 88
4.2 Device connections to heating system Inch G 1 1/4'' external G 1 1/4'' external
4.3 Device connections to additional heat exchanger
(waste heat recovery) Inch
G 1 1/4'' external G 1 1/4'' external
4.4 Air duct inlet and outlet (min. internal dimensions) L x W cm 50 x 50 57 x 57
4.5 Weight of the transportable unit(s) incl. packing kg 222 260
5 Electrical connection
5.1 Nominal voltage; fuse protection V / A 400 / 16 400 / 20
5.2 Nominal power consumption
2
A2 W35 kW
2.74 2.86 3.8 4.0
5.3 Starting current with soft starter A 23 25
5.4 Nominal current A2 W35 / cos ϕ A / --- 4.9 / 0.8 5.16 / 0.8 6.9 / 0.8 7.2 / 0.8
6 Complies with the European safety regulations
3
3. See CE declaration of conformity
3
7 Additional model features
7.1 Defrosting Automatic Automatic
Type of defrosting Reverse cycle Reverse cycle
Defrosting tray included Yes (heated) Yes (heated)
7.2 Heating water in device protected against freezing
Yes
4
4. The heat circulating pump and the heat pump controller must always be ready for operation.
Yes
4
7.3 Performance levels 1 1
7.4 Controller internal/external Internal Internal