18
12.3.5 Heating mode LA 10MR
APPENDIX: 12.3 SCHEMATICS
0
2
4
6
8
10
12
14
16
-20-100 10203040
Lufteintrittstemperatur in [°C]
Heizleistung in [kW]
35
50
Wasseraustrittstemperatur in [°C]
0
1
2
3
4
-20-100 10203040
Lufteintrittstemperatur in [°C]
Leistungsaufnahme (incl. Pumpenleistungsanteil)
50
35
0
1
2
3
4
5
6
7
-20-100 10203040
Lufteintrittstemperatur in [°C]
Leistungszahl (incl. Pumpenleistungsanteil)
35
50
40
0
2000
4000
6000
8000
10000
12000
14000
16000
18000
0 0,5 1 1,5 2 2,5
Heizwasserdurchsatz in [m³/h]
Druckverlust in [Pa]
Verflüssiger
Bedingungen:
Heizwasserdurchsatz 1,5 m³/h
40
40
Heating capacity in [kW]
Conditions:
Heating water flow rate 1.5 m
3
/h
Water outlet temperature in [°C]
Air inlet temperature in [°C]
Power consumption (incl. power input to pump)
Pressure loss in [Pa]
Condenser
Air inlet temperature in [°C]
Coefficient of performance (incl. power input to pump)
Air inlet temperature in [°C]
Heating water flow rate in [m
3
/h]
0 0,5 1 1,5 2 2,5