470
207
115
x
Dimensions
(millimetres)
Air Warmer: Model No. HAW1000N
Installation and Operating Instructions
Fig. 1
08/50511/0 Issue 0
Watts Electrical Supply Weight (kg)
HAW1000N 1000 230-240V ~1PN 14
Important Safety Advice
Do not locate above or below a fixed socket outlet.
The heater including the supporting legs can get very hot;
therefore do not mount directly on any combustible
material. Suitable fire resistant material is required
between the heater and any combustible base or support.
Warning: Before obtaining access to the terminals all supply
circuits must be disconnected.
The heater should be installed to allow a reasonable air
flow around the heater.
A prominent notice should be provided where the heater
is sited ‘Keep Clear and Unobstructed’.
Avoid exposure to water.
The heaters are not suitable for general domestic use.
The heater is suitable for a drying room provided that the
heater has suitable ventilation.
A mains lead which can operate at + 110°C must be used.
An all-pole isolating switch with a minimum separation of
3mm in each pole must be fitted adjacent to the heater to
facilitate local isolation.
General
This carton contains:
• 1 HAW1000N heater
• 1 Foldable guard
Electrical connection
WARNING – THIS APPLIANCE MUST BE EARTHED.
Verify that the electrical supply cable is sufficient for the rated loading.
Check that the incoming supply conforms to the rated supply.
The heater power circuit must be protected by a suitably rated over
current device.
The incoming cables must be connected to the factory fitted heater
terminals provided. Do not alter any factory fitted wiring.
The Terminal Cover Casting can be removed to access the terminals, by
removing the 2 screws fixing the cover - see Fig. 2.
WARNING: Ensure the power cable path does not come into contact
with the heater element.
The heater is supplied with an earth stud, located inside the terminal box,
which must be connected to earth.
After connection check the continuity of earth connections.
Installation
The installation should be carried out by a suitably qualified electrician/
engineer in accordance with applicable standards.
Remove all items from the packaging. The heater should be fixed using
the fixing points provided - see Fig. 3. Ensure the heater is securely
fastened.
Remove the terminal cover and connect the mains cable, while making
note of the path the connecting cable should take through the guard.
Reattach the terminal cover to the heater and fasten the cable gland.
Mount the guard over the heater. Ensure the guard is mounted centrally
relative to the heater as shown in Fig. 4.
The heater should not be connected until the instruction leaflet has been
read fully.
Fig. 2
449
179
Fig. 3
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE