Dimplex Electric Fireplace Indoor Fireplace User Manual


 
Warning:
Allow at least 10 minutes for the light bulbs and heater to cool before attempting any
maintenance or cleaning.
Bulb Requirements
Quantity 2 clear chandelier or candelabra bulbs with an E-12 (small) socket base, 60 watt
rating. Example: GE 60BC or Philips 60CTC
Tools required:
Philips screwdriver
1. Remove the fireplace trim.
2. With a Philips screwdriver remove the two outer screws from the log grate.
3. Slide the light assembly out of the insert by pulling the log grate
until the light assembly reaches the stop (approximately 2”)
4. Remove the log set by lifting straight up.
5. Disconnect the log set LED wire harness from the units
6. Examine the bulb(s) to determine which bulb(s) require replacement.
7. Unscrew the bulbs counter clockwise.
8. Insert new bulbs.
9. Re-connect the log set LED wire harness to the unit
10. Replace the log set into the insert.
11. Slide the light assembly back into the insert.
12. Install the two outer screws into the log grate.
13. Reinstall the fireplace trim.
5
LED Wire
Harness
Lo
g
Assembl
y
Li
g
ht Bulbs
Outer Screw
Light
Assembly
Note: Log set fits
tightly into firebox,
some force may be
necessary to remove