Dimplex DXDF20 Fan User Manual


 
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
DXDF20 & DXDF20L 2kW Fan Heater
IMPORTANT SAFETY ADVICE
DO NOT use the heater on deep pile carpets or the long
hair type of rugs, or less than 750mm away from any
overhanging surface. Keep combustible materials such
as drapes and other furnishings clear from the front, sides
and rear of the heater. Do not use heater to dry your laundry.
DO NOT use the heater in the immediate surroundings of a
bath, a shower or a swimming pool.
DO NOT place the heater directly below a fixed socket
outlet.
The socket-outlet must be accessible at all times to enable
the mains plug to be disconnected as quickly as possible.
DO NOT COVER or obstruct the air inlet and outlet openings
in any way.
The heater must be on a flat stable surface when in use.
DO NOT operate the heater with the mains lead overhanging
the front outlet grille.
NEVER leave the heater unattended when it is used by or
near the aged, infirm person’s or children.
THE HEATER CARRIES THE WARNING SYMBOL
INDICATING THAT IT MUST NOT BE COVERED.
The instruction leaflet belongs to the appliance and must
be kept in a safe place. If changing owners, the leaflet
must be surrendered to the new owner.
IMPORTANT – If the mains lead of this appliance is damaged,
it must be replaced by the manufacturer or its service
agent or a similarly qualified person in order to avoid a
hazard.
WARNING: In order to avoid a hazard due to inadvertent
resetting of the thermal cut-out, this appliance must not
be supplied through an external switching device, such as
a timer, or connected to a circuit that is regularly switched
on and off by the utility.
Electrical connection
This heater must be used on an A.C.~ supply only and the voltage
marked on the heater must correspond to the supply voltage.
This heater is fitted with a plug incorporating a 13 amp fuse.
When replacing the fuse, a 13 amp fuse approved by ASTA to BS
1362 must be used.
If the plug is not suitable for the socket outlets in your home, the
plug must be cut off and an appropriate one fitted. A plug cut off
from a mains lead will give a shock hazard if inserted into a 13
amp socket elsewhere in the house. To avoid this, it should be
disposed of immediately.
NOTE: The fuse cover of a non-rewirable plug must be refitted
when changing the fuse. Should the cover become lost, the plug
must not be used until the correct replacement fuse cover is
obtained from your supplier or by contacting our customer
helpline.
IMPORTANT : The wires in this mains lead are coloured in
accordance with the following code :
BLUE : NEUTRAL
BROWN : LIVE
As the colours of the wires in the mains lead may not correspond
with the coloured markings in your plug, proceed as follows :
Connect the BROWN wire to the terminal marked ‘L’ or coloured
RED. Connect the BLUE wire to the terminal marked ‘N’ or coloured
BLACK. Note :L’ or ‘N’ must not be connected to the EARTH
terminal marked ‘E’ or
or coloured GREEN or GREEN AND
YELLOW.
If in doubt, consult your electrician.
General
The heater has a loading of 2kW.
Heat output and temperature control on this appliance are
provided using the electronic control. With the unit plugged in,
and by pressing the ‘STAND-BY’ button (see ‘1’ in Fig. 4) the
heater can be turned on. The appliance is provided with a handle
for easy carrying - see Fig. 3.
Operation - see Fig. 4
The heat output is electronically controlled, according to the room
temperature.
To switch the appliance On/Off press button ‘1’.
Press button ‘2’ to select Fan only/Low heat/High heat. By
pressing this button once Fan only is selected, pressing twice
provides Low heat and by pressing three times High heat is
selected.
On the display screen (see Fig. 4) two temperature readings
appear at the top of the screen. The room ambient temperature
appears on the right and the desired temperature appears on
the left hand side.
Use buttons ‘3’ and ‘4’ to set the desired room temperature
when Low or High heat is selected.
The temperature can be set from 5
o
C to 35
o
C and this will be
shown on the display. When the temperature is reached the
heater will automatically switch off. If the ambient temperature
drops the heater will come on again automatically. Note the
electronic climate control device conserves energy and assists
with temperature regulation e.g. if the heater is set to HIGH heat
and the temperature is set to 28
o
C, at 27
o
C the heater will switch
to LOW heat. Then at 28
o
C the heater will switch OFF completely.
An audible beep can be heard when any button is pressed.
A double beep can be heard when 5° and 35° is selected; the
upper and lower limits.
By keeping buttons ‘3’ and ‘4’ pressed down the user can scroll
quickly to the desired temperature.
Note: The heater retains it’s last setting once the appliance has
been switched off or disconnected from the power supply.
Overheat cut-out
The built-in overheat cut-out switches off the appliance
automatically in the event of a fault. Disconnect the mains plug
from the socket. After a short cooling down phase, the appliance
switches into stand-by mode and is ready for use again. If the
fault should occur again, see your local dealer.