Dimplex DFPI2311 Indoor Fireplace User Manual


 
15
HFPI9280, DFPI2311
If the unit was operating prior to servicing allow at least 10 minutes for light bulbs and
heating element to cool off to avoid accidental burning of skin.
Disconnect power before attempting any maintenance or cleaning to reduce the risk of
electric shock or damage to persons.
TO REPLACE THE HEATER DISABELER SWITCH
1. Remove the glass doors and trim from the unit and remove it from the opening.
2. Unscrew the screws located in the middle of the top and the two screws at the back of
the top.
3. Remove the top being careful not to damage any of the attached wiring.
4. Locate and remove the heater disabler switch located on the side of the unit by
depressing the retainer clips on the rear of the switch and pushing the switch out of
the front of the unit.
5. Disconnect the wiring clips and connections noting their original locations and remove
the heater assembly.
6. Properly orientate the new switch and connect all of the wiring clips and connections.
7. Reassemble in the reverse order as above.