Dimplex CFP3811GB Indoor Fireplace User Manual


 
RESETTING THE TEMPERATURE CUTOFF
SWITCH
Should the heater overheat, an automatic cut out will
turn the heater off and it will not come back on
without being reset. It can be reset by switching the
MAIN ON/OFF SWITCH to OFF and waiting 5
minutes before switching the unit back on.
CAUTION
If you need to continuously reset the heater, unplug
the unit and call customer service at
1-800-668-6663.
MAINTENANCE
WARNING: Always disconnect from the power
supply before attempting any maintenance.
7
Bulb Replacement - see Fig.’s 3, 4 and 5
The bulbs are located behind the back panel. To
gain access to the bulbs, the screws indicated in
Fig. 3 (4 screws) which secure the back panel,
mustt be removed.
Remove and slide out panel as indicated on Fig. 4.
Remove the defective lamp by unscrewing it as
shown in Fig. 5.
Replace with a 60W E12 clear chandelier or
candelabra. Take care not to over-tighten the bulb.
Refit the back panel and secure with the screws.
To remove the firebox insert prior to repair, please
remove the 8 srews at the back (Fig 3) and slide
outto the front as shown