Desa WMP10 Gas Heater User Manual


 
www.desatech.com
123995-01C16
1/2 GLASS HEIGHT
CORRECT FLAME PATTERN
AT HIGH POSITION
INCORRECT FLAME PATTERN
AT HIGH POSITION
1/2 GLASS HEIGHT
1/2 GLASS HEIGHT
CORRECT FLAME PATTERN
AT HIGH POSITION
INCORRECT FLAME PATTERN
AT HIGH POSITION
1/2 GLASS HEIGHT
Figure 23 - Correct Burner Flame Pattern
Yellow
Tipping
Figure 24 - Incorrect Burner Flame
Pattern
BURNER FLAME PATTERN
INFRARED MODELS
Figure 25 shows a correct burner ame pat-
tern. Figure 26 shows an incorrect burner
ame pattern.
If burner ame pattern is incorrect, as shown
in Figure 26
turn heater off (see To Turn Off Gas to Ap-
pliance, page 14)
see Cleaning, page 17
Figure 26 - Incorrect Burner Flame
Pattern (Dual Burner Shown)
Figure 25 - Correct Burner Flame Pattern
(Dual Burner Shown)
INSPECTING BURNER
Continued
WARNING: If yellow tipping
occurs, your heater could pro-
duce increased levels of carbon
monoxide. If burner ame pattern
shows yellow tipping, proceed
with the following instructions.
NOTICE: Do not mistake orange
ames with yellow tipping. Dust
or other ne particles enter the
heater and burn causing brief
patches of orange ame.
BURNER FLAME PATTERN BLUE
FLAME MODELS
Figure 23 shows a correct burner ame pat-
tern. Figure 24 shows an incorrect burner
ame pattern. The incorrect burner ame
pattern shows yellow tipping of the ame.
It also shows the ame higher than 1/2 the
glass panel height.
If burner ame pattern is incorrect, as shown
in Figure 24
turn heater off (see To Turn Off Gas to Ap-
pliance, page 14)
see Cleaning, page 17
(Models GWN6 and GWP6 will be lower due to