Desa HD-9140 Home Safety Product User Manual


 
-6-
595-5660-06
When wiring to additional standard fix-
tures: Connect the sensor's red wire to the
standard light's black wires. Connect all white
wires together. Total fixture ratings must not
exceed 1000W (8.3 A).
NOTE: All wiring between fixtures should be run
in accordance with the National Electrical Code
through conduit or another acceptable means.
Contact a qualified electrician if there is any
question as to the suitability of the system.
This sensor has a rating of 1000W. If your fix-
ture is only rated 300W, 700W of additional
load may be controlled by this sensor.
When determining what a fixture is rated for,
do not simply look at the rating on the lamp in
the fixture. Look at the marking which speci-
fies the maximum lamp wattage for which the
fixture is suitable.
Once you have selected the fixtures to be con-
nected and determined their maximum ratings,
add these ratings up. For instance, if you have
3 fixtures rated 100W, 150W, and 75W respec-
tively, you have a total load of 325W.
(Standard)
Wiring to a Motion Light & Standard Fixture
Controlling Additional Fixtures With Your JourneyMan
®
Replacement Motion Sensor
RED from
JourneyMan
®
to
BLACK from Fixture
BLACK from Switch
to BLACK from
JourneyMan
®
WHITE from Line
to WHITE from
JourneyMan
®
WHITE from Line
to WHITE from
Fixture