INSTALLATION AND CLEARANCES

WARNING: Maintain the





Side Wall 16", Ceiling 42", Front 36"

Height 17", Depth 14", Front Width 24",
Rear Width 20" (measured at 14" depth).
Carefully follow instructions below. This
will ensure safe installation into a masonry,
UL127-listed manufactured replace or certi-
ed vent-free rebox.
Minimum Clearances For Side


A. Clearances from side of replace cabinet
to any combustible material and wall
should follow diagram in Figure 4.
Example: The face of a mantel, bookshelf,
etc. is made of combustible material and
protrudes 3
1
/2" from the wall. This com-
bustible material must be 4" from the side
of the replace cabinet (see Figure 4).
Note: When installing your gas logs into
a manufactured rebox, follow rebox
manufacturer’s instructions for minimum
clearances to combustible materials.
B. Clearances from the top of the replace
opening to the ceiling should not be less
than 42".
Figure 4 - Minimum Clearance for
Combustible to Wall
*Minimum 16" from Side Wall
*
Example
INSTALLATION
Continued
NOTICE: Manual control heaters

If so, you must always run heater


-

Installing Damper Clamp Accessory
for Vented Operation

Clearances

Note: If using a mantel, proceed to If Using
Mantel, page 10. If not using a mantel, follow
the information below.
You must have noncombustible material(s)
above the replace opening. Noncombustible
materials (such as slate, marble, tile, etc.) must
be at least 1/2" thick. With sheet metal, you
must have noncombustible material behind it.
Noncombustible material must extend at least 8"
up. See Figure 5 for minimum clearances.

 
 
12" or more Noncombustible material okay.
Between 8" and 12"
Noncombustible material okay.
Less than 8" Noncombustible material must
be extended to at least 8".
See Between 8" and 12",
above. If you cannot extend
material, you must operate
heater with ue damper open.
Heat Resistant
Material
(A)
Figure 5 - Heat Resistant Material (Slate,
Marble, Tile, etc.) Above Fireplace