Desa (V)V36N-B SERIES, VV36NC1 SERIES Indoor Fireplace User Manual


 
111252-01E
For more information, visit www.desatech.com
For more information, visit www.desatech.com
3
3
SAFETY INFORMATION
Continued
PRODUCT IDENTIFICATION
Figure 1 - Direct-Vent Fireplace with Millivolt Ignition
SAFETY INFORMATION
LOCAL CODES
PRODUCT IDENTIFICATION
Glass
Door
Assembly
Blower Switch
(BKT Standard with
CHDV Models)
Piezo
Ignitor
Control
Valve
Log
Set
Grate
Assembly
Lava
Rock
Glowing
Embers
Upper Louver
Panel
Lower
Louver
Panel
Flue Collar
Nailing
Flange
ON/OFF/REMOTE Switch
(Optional Installation)
8. Turn fireplace off and let cool before servicing, installing, or
repairing. Only a qualified service person should install, ser-
vice, or repair this fireplace. Have fireplace inspected annu-
ally by a qualified service person.
9. You must keep control compartments, burners, and circulating
air passages clean. More frequent cleaning may be needed due
to excessive lint and dust from carpeting, bedding material,
etc. Turn off the gas valve and pilot light before cleaning fire-
place.
10. Have venting system inspected annually by a qualified service
person. If needed, have venting system cleaned or repaired.
See Cleaning and Maintenance, page 28.
11. Keep the area around your fireplace clear of combustible ma-
terials, gasoline, and other flammable vapor and liquids. Do
not run fireplace where these are used or stored. Do not place
items such as clothing or decorations on or around fireplace.
12. Do not use this fireplace to cook food or burn paper or other
objects.
13. Do not use any solid fuels (wood, coal, paper, cardboard, etc.)
in this fireplace. Use only the gas type indicated on fireplace
nameplate.
14. This appliance, when installed, must be electrically grounded
in accordance with local codes or, in the absence of local codes,
with the National Electrical Code, ANSI/NFPA 70, or the Ca-
nadian Electrical Code, CSA C22.1.
15. Do not use fireplace if any part has been exposed to or under
water. Immediately call a qualified service person to arrange
for replacement of the unit.
16. Do not operate fireplace if any log is broken.
17. Do not use a blower insert, heat exchanger insert, or other ac-
cessory not approved for use with this fireplace.
18. Do not operate fireplace with glass door removed, cracked, or
broken.
19. Provide adequate clearances around air openings.
LOCAL CODES
Install and use fireplace with care. Follow all local codes. In the
absence to local codes, use the current National Fuel Gas Code
ANSI Z223.1/NFPA 54* (USA) or the current CSA-B149.1 Instal-
lation Code (Canada).
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269