Desa VN600BA Gas Heater User Manual


 
11
104271
OWNER’S MANUAL
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
1. Turn control knob clockwise
Clockwise
to the PILOT position.
2. Press in control knob and turn clock-
wise
Clockwise
to the OFF position.
Shutting Off Burner Only (pilot
stays lit)
Turn control knob clockwise
Clockwise
to
the PILOT position.
Thermocouple
Pilot Burner
Ignitor Electrode
Figure 16 - Pilot
OPERATING
HEATER
Continued
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information
page 10, column 3.
2. Make sure equipment shutoff valve
is fully open.
3. Turn control knob clockwise
Clockwise
to the OFF position.
4. Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow "B" in the safety in-
formation at the top of column 3,
page 10. If you don’t smell gas, go to
the next step.
5. Press in control knob and turn coun-
terclockwise
C-clockwise
to the PILOT
position. Keep control knob pressed
in for five (5) seconds (see Figure 15).
Note:
You may be running this
heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds. This will allow air to
bleed from the gas system.
If control knob does not pop up
when released, contact a qualified
service person or gas supplier for
repairs.
6. With control knob pressed in, push
down and release ignitor button. This
will light pilot. The pilot is attached
to the front of burner. The pilot can
be seen through the glass panel. If
needed, keep pressing ignitor button
until pilot lights.
Note:
If pilot does not stay lit, refer
to Troubleshooting, pages 13 through
15. Also contact a qualified service
person or gas supplier for repairs.
Until repairs are made, light pilot
with match. To light pilot with match,
see Manual Lighting Procedure.
OFF
HIGH
PILOT
LOW
IGNITOR
Control Knob
Figure 15 - Control Knob In The OFF
Position
Ignitor Button
1. Remove front panel (see Figure 10,
page 8).
2. Follow steps 1 through 5 under Light-
ing Instructions.
3. With control knob pressed in, strike
match. Hold match to pilot until pi-
lot lights.
4. Keep control knob pressed in for 30
seconds after pilot is lit. After 30 sec-
onds, release control knob. Follow
step 8 under Lighting Instructions.
5. Replace front panel.
MANUAL LIGHTING
PROCEDURE
7. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
Note:
If pilot goes out, repeat steps
3 through 7.
8. Turn control knob counterclockwise
C-clockwise
to the HIGH position. The
main burner should light. Set control
knob to any heat level between HIGH
and LOW. To turn control knob from
HIGH to a lower setting, press in the
control knob and turn counterclock-
wise
C-clockwise
.
Note:
Both HIGH and LOW are
locked positions. You must press in
control knob before turning it from
these positions.