Desa VN1800C Electric Heater User Manual


 
22
100750
4. Wait five minutes to clear out any gas. Then smell for gas, including near
the floor. If you smell gas, STOP! Follow “B” in the safety information at
the top of page 21. If you don’t smell gas, go to the next step.
5. Press in control knob.
Note:
You may be running this heater for the first time after hooking up
to gas supply. If so, you may need to press in control knob for 30 seconds.
This will allow air to bleed from the gas system.
If control knob does not pop up when released, contact a qualified
service person or supplier for repairs.
6. Keep control knob pressed in and turn it counterclockwise
C-clockwise
to the
PILOT/IGN position. This will light pilot.
Note:
You will hear a loud “click” when the control knob reaches the
PILOT/IGN position.
If pilot does not light
turn control knob clockwise
Clockwise
to the OFF position
repeat steps 5 and 6
If pilot does not stay lit after several tries
refer to Troubleshooting, pages 26 through 29
contact a qualified service person or gas supplier
Until repairs are made, light pilot with match. To light pilot with match, see
Manual Lighting Procedure, page 24.
7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30
seconds, release control knob.
Note:
If pilot goes out, repeat steps 3 through 7.
Ignitor Electrode
Pilot Burner
Thermocouple
OPERATING
HEATER
Models VN1800C
and VN3000C
Continued
Figure 20 - Pilot
Continued