16
www.desatech.com
116240-01A
Figure 25 - Blower Model BK
Magnetic Strips
Exhaust
Port
Screw
Green
Ground
Wire
Spade Terminals
Side View
Lower Firebox
Cavity
Blower
Location
VENTING INSTALLATION
INSTRUCTIONS
Continued
FIREPLACE INSTALLATION
CHECK GAS TYPE
Use proper gas type for the fireplace unit you are installing. If your
gas supply is not correct, do not install fireplace. See retailer where
you purchased the fireplace for proper fireplace according to your gas
type or to purchase gas conversion kit (see
Accessories, page 34).
INSTALLING OPTIONAL BLOWER
ACCESSORY
NOTICE: If installing blower in an existing fireplace
with gas connections, shut off gas supply and dis-
connect heater from gas supply. Contact a qualified
service person to do this.
WARNING: If there is a duplex electrical outlet
installed in the right side of the bottom of the fireplace
base area, be sure that the electrical power to the outlet
is turned off before proceeding with blower installation.
Failure to do this may result in serious injury.
Model BK Installation
Follow all instructions provided in the blower accessory kit.
1. Attach the power cord to the blower motor by firmly pushing the
two female terminals at the end of the power cord onto the two
spade terminals on the blower motor (see Figure 25).
2. Attach green ground wire from power cord to blower hous
-
ing using screw provided (see Figure 25). Tighten screws
securely.
3. Place the blower against the lower rear wall of the firebox outer
wrapper with the exhaust port directed upward. The blower will
fit inside the back opening and be held in position against the
back wall by the magnets (see Figure 25).
4. Be certain that all wire terminals are securely attached to ter
-
minals on blower motor and that the screw retaining the green
ground wire is tight.
VENTING INSTALLATION INSTRUCTIONS
Parts List for Venting Kits and Components
FIREPLACE INSTALLATION
Check Gas Type
Installing Optional Blower Accessory
PARTS LIST FOR VENTING KITS AND
COMPONENTS
DESA (5/8") Pipe & Vent Kits
Number Description
P58-6 6" Section Double Wall Pipe, Galvanized
P58-12 12" Section Double Wall Pipe, Galvanized
P58-24 24" Section Double Wall Pipe, Galvanized
P58-36 36" Section Double Wall Pipe, Galvanized
P58-48 48" Section Double Wall Pipe, Galvanized
PA58-712 Adjustable 7"-12" Section Double Wall Pipe, Galva-
nized
E58-45 45
° Elbow, Galvanized
E58-90 90° Elbow, Galvanized
VKG-58 Ground Floor Vent Kit, Galvanized (Includes: 45° El
-
bow, 7"-12" Adjustable Pipe, Wall Firestop, Horizontal
Square Termination, 16 Screws)
VKB-58 Basement Vent Kit, Galvanized (Includes: 45° Elbow,
7"-12" Adjustable Pipe, Wall Firestop, Horizontal
Square Termination, 4' Pipe, 90° Elbow, 20 Screws)
VKS-58 Snorkel Vent Kit, Galvanized (Includes: 45° Elbow,
7"-12" Adjustable Pipe, Wall Firestop, 36" Snorkel
Termination, 4' Pipe, 1' Pipe, 90° Elbow, 26 Screws)
VKR-58 Roof Vent Kit, Galvanized (Includes: 45° Elbow, 7"-12"
Adjustable Pipe, Flue Restrictor, Vertical High Wind
Termination, 2' Pipe, 4' Pipe, Wall Firestop, Storm
Collar, Roof Flashing [0/12 - 6/12], 26 Screws)
VKC-58 Corner Vent Kit, Galvanized (Includes 45° Elbow,
7"-12" Adjustable Pipe, Wall Firestop, Horizontal
Termination, 6" Pipe, 90° Elbow, 18 Screws)
HTK-58 Horizontal Round Termination Kit (Includes Round
Termination, Wall Firestop, 45° Elbow)
HT-58 Horizontal Round Termination, Galvanized
HTS-58 Horizontal Square Termination, Galvanized
HTKS-58 Horizontal Square Termination Kit (Includes: Square
HTS-58 Horizontal Square Termination, Gal
-
vanized
VT-58 Vertical Round Termination, Galvanized
ST-58-14 14" Snorkel Termination, Galvanized
ST-58-36 36" Snorkel Termination, Galvanized
SC-58 Storm Collar, Galvanized
WF-58 Wall Firestop, Galvanized
RF-58-6 Roof Flashing - 0 to 6/12 Pitch, Galvanized
RF-58-12 Roof Flashing - 6/12 to 12/12 Pitch, Galvanized
VR-58 Vertical Restrictor, Galvanized
S-58 Vinyl Siding Standoff, Galvanized
WS-58 Wall Strap
CS-58 Cathedral Ceiling Support
FP-58 Firestop Plate
SF-58 Stucco Flashing - For use with HTS-58