www.desatech.com
112882-01E
22
Figure 34 - Incorrect Pilot Flame Pattern
Figure 33 - Correct Pilot Flame Pattern
Pilot Burner
Propane/LP Gas
Natural Gas
Thermocouple
OPERATING HEATER
Continued
Pilot Burner
Thermocouple
Propane/LP Gas Natural Gas
MAIN BURNER
Periodically inspect all burner flame holes with
the heater running. All slotted burner flame holes
should be open with yellow flame present. All
round burner flame holes should be open with a
small blue flame present. Some burner flame holes
may become blocked by debris or rust, with no
flame present. If so, turn off heater and let cool.
Remove blockage, blocked burner flame holes
will create soot.
INSPECTING BURNERS
Check pilot flame pattern and burner flame pat-
terns often.
PILOT FLAME PATTERN
Figure 33 shows a correct pilot flame pattern.
Figure 34 shows an incorrect pilot flame pattern.
The incorrect pilot flame is not properly heating
the thermocouple. When the thermocouple cools,
the heater will shut down. If pilot flame pattern is
incorrect, as shown in Figure 34
• turn heater off (see To Turn Off Gas to Appli
-
ance, page 20)
• see Troubleshooting
, page 24
Note: The pilot flame on natural gas units will
have a slight curve, but the flame should be blue
and have no yellow or orange color.
4. Press the POWER and LOCK buttons
together to turn off the fireplace
Note: Do not leave the hand-held remote in
the AUTO mode close to the fireplace. The
radiant heat from the fireplace will turn off the
fireplace. Ideally, place the hand-held remote
in the center of the room facing towards the
fireplace.
Note: Do not hold the hand-held remote for
a long time. Body temperature will affect its
operation in the AUTO mode.
Safety Features
When away from home for an extended period
of time or as a child safety feature to prevent
accidental ignition of the fireplace, the receiver
ON/OFF/REMOTE switch should be in the
OFF position.
Auto Shutoff Feature
1. If the average room temperature exceeds
82 degrees Fahrenheit (28 degrees Centi-
grade), the hand-held remote control will
perform a safety override and shut the
fireplace off. This feature is not available
in the MANU mode.
2. The receiver continuously receives signals
from the hand-held remote to control the
room temperature. If the hand-held remote
is misplaced, obstructed or for any reason
cannot transmit to the receiver, the receiver
will shut off the fireplace after 8 minutes.
Key Pad Lock Feature
This feature allows the user to lock/unlock
the keypad on the hand-held remote in the
MANU or AUTO mode to prevent inadvertent
operation (i.e. children operating the hand-held
remote control, etc.). The keypad is locked in
either on or off. Press the POWER and LOCK
buttons together to turn the unit on or off.