Desa (V)C36I Indoor Fireplace User Manual


 
www.desatech.com
107777-01E6

Fan or blower kit is optional with this replace
(circulating models only). Use of blowers or
fans other than those manufactured by DESA
Heating, LLC voids warranty. Fan is operated
by pressing rocker switch (see Figure 6) in
lower right hand corner of fireplace face.
Blower is operated by turning control knob
(not shown).
Fan/blower kit electrical connections are
made through the electrical cover plate on
side of replace a shown in Figure 6.
FIREPLACE INSTALLATION
Continued
12
1
/
4
" Ref.
6"
Ref.
12" Min.
9" Min.
1
1
/
2
" Max.
3" Nom.
33°
Combustible
Material
Safe
Zone for
Projection of
Combustible
Materials
Fireplace Opening
Upper
Section of
Fireplace
Figure 4 - Mantel Clearances to
Combustible Material (with Louver)
Wiring Instructions
1. Remove electrical cover plate with bush-
ing from replace by removing 2 sheet
metal screws as shown in Figure 6.
2. Slide power source wiring through electri-
cal bushing opening and electrical cover
plate and make all necessary connec-
tions.
3. Slide all wiring connections in electrical
housing as shown in Figure 6.
4. Secure electrical cover plate with screws
previously removed.
Note: Electrical housing and cover plate have
sharp edges. Wear protective gloves.

A mantel may be installed if desired (see
Figures 4 and 5). Woodwork such as wood
trims, mantels or any other combustible
material projecting from front face, must not
be placed within 9" of replace opening and
within 6" of top louver opening. Combustible
materials above 9" and projecting more than
1
1
/
2
" from replace must not be placed less
than 12" from top opening of replace (NFPA
STD 211, Sec. 7-3.3.3).
Figure 5 - Mantel Clearances to
Combustible Material (without Louver)
12
1
/
4
" Ref.
1
1
/
2
"
Max.
Upper Section
of Circulating
Fireplace
6"
Ref.
6"
Min.
33°
3" Nom.
*Note: Drawing
Not To Scale
Safe Zone For
Projection of
Combustible
Materials
Combustible
Material
12"
Min.
9"
Min.
Fireplace Opening
Top of
Louvered
Opening
Electrical
Bushing
Electrical
Cover
Plate
Rocker
Switch
Figure 6 - Fan Switch-Electrical Bushing
Electrical
Housing
Wire Nut (3x)
(Not Supplied)
Outer Wrapper
of Fireplace
Electrical Cover
Plate and
Electrical Bushing
Fireplace Chassis
Ground
To Power
Source
Receptacle
(Supplied)
Power Source Wiring
(Not Supplied)
Prewired Receptacle
and Ground
Sheet
Metal
Screws