OPERATING FIREPLACE
Optional Hand-Held Remote Operation (Cont.)
Optional Blower Operation
OPERATING FIREPLACE
Continued
Locate the blower switch by opening lower louver on fireplace.
Blower switch is located at lower right inside louver door.
The GA3700T Series thermostat-controlled blower has a vari-
able speed control with an ON/OFF switch. The blower will
start when the thermostat senses a sufficient increase in firebox
temperature. The GA3700 variable speed blower also has an
ON/OFF switch built into the variable speed control.
Note for GA3700T Series Only:
If you are using GA3700T
blower, your fireplace and blower will not turn on and off at the
same time. The fireplace may run for several minutes before the
blower turns on. After the heater modulates to the pilot position,
the blower will continue to run. The blower will shut off after the
firebox temperature decreases.
Note:
It is safe to operate fireplace with blower turned off. However,
the blower helps distribute heated air from the fireplace.
Follow installation instructions included with the blower accessory.
OPTIONAL BLOWER
OPERATION
Figure 43 - Thermostat Hand-Held Remote Control Unit (GHRCTB)
Turns Hand-Held
Remote On or Off
and Allows You to
Choose the Manual
Setting
Selects Auto
Setting
Increases Room
Temperature in
AUTO Mode
Locks System to
Prevent Accidental
Ignition
Digital Display
Shows
Temperature and
Settings
Turns Burners
On or Off
Decreases Room
Temperature in
AUTO Mode
THERMOSTAT SERIES (MODEL GHRCTB)
The hand-held remote can be operated using either the manual
mode (MANU) or thermostatic mode (AUTO) (see Figure 43).
To select Fahrenheit/Centigrade mode display, carefully press
the ˚C/˚F mode button with the end of a paper clip or similar
blunt object.
Manual Mode
1. Press the POWER and LOCK buttons together to turn on
the hand-held remote control.
2. Press the MANU button to turn on the fireplace.
3. Press the POWER and LOCK buttons together to turn off
the fireplace.
Auto (Thermostatic) Mode
1. Press the POWER and LOCK buttons together to turn on
the hand-held remote control.
2. Press AUTO button to select this mode.
3. Set the desired room temperature by pressing the TEMP
+ or - buttons.
4. Press the POWER and LOCK buttons together to turn off
the fireplace
Note:
Do not leave the hand-held remote in the AUTO mode
close to the fireplace. The radiant heat from the fireplace will
turn off the fireplace. Ideally, place the hand-held remote in the
center of the room facing towards the fireplace.
Note:
Do not hold the hand-held remote for a long time. Body
temperature will affect its operation in the AUTO mode.
Safety Features
When away from home for an extended period of time or as a
child safety feature to prevent accidental ignition of the fire-
place, the receiver ON/OFF/REMOTE switch should be in the
OFF position.
Auto Shutoff Feature
1. If the average room temperature exceeds 82 degrees Fahr-
enheit (28 degrees Centigrade), the hand-held remote con-
trol will perform a safety override and shut the fireplace
off. This feature is not available in the MANU mode.
2. The receiver continuously receives signals from the hand-
held remote to control the room temperature. If the hand-
held remote is misplaced, obstructed, or for any reason
cannot transmit to the receiver, the receiver will shut off
the fireplace after 8 minutes.
Key Pad Lock Feature
This feature allows the user to lock/unlock the keypad on the
hand-held remote in the MANU or AUTO mode to prevent
inadvertent operation (i.e. children operating the hand-held re-
mote control, etc.). The keypad is locked in either on or off. Press
the POWER and LOCK buttons together to turn the unit on or off.