Desa SMA18VNA Electric Heater User Manual


 
www.desatech.com
114744-01C 25
WARNING: If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your
building.
• Immediately call your gas supplier from a neighbor’s phone. Fol-
low the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint,
paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These
fumes may mix with combustion air and create odors. These odors will disappear over time.
TROUBLESHOOTING
Continued
POSSIBLE CAUSE
1. Heater burning vapors from
paint, hair spray, glues, clean
-
ers, chemicals, new carpet,
etc. (See IMPORTANT state-
ment above)
2. Low fuel supply (propane/LP
only)
3. Gas leak. See warning state
-
ment at top of page
1. Not enough fresh air is avail
-
able
2. Low line pressure
3. ODS/pilot is partially
clogged
1. Gas leak. See warning state
-
ment at top of page
2. Control valve or gas control
defective
1. Foreign matter between con
-
trol valve and burner
2. Gas leak. See warning state
-
ment at top of page
1. Hand-held remote control is
too close to heater
REMEDY
1. Open window to ventilate
room. Stop using odor caus
-
ing products while heater is
running
2. Refill supply tank (propane/LP
only)
3. Locate and correct all leaks (see
Checking Gas Connections,
page 14)
1. Open window and/or door for
ventilation
2. Contact local natural or pro
-
pane/LP gas company
3. Clean ODS/pilot (see Cleaning
and Maintenance, page 21)
1. Locate and correct all leaks
(see Checking Gas Connec
-
tions, page 14)
2. Replace control valve or gas
control
1. Take apart gas tubing and
remove foreign matter
2. Locate and correct all leaks (see
Checking Gas Connections,
page 14)
1. Move hand-held remote con
-
trol unit farther away from the
heater
OBSERVED PROBLEM
Heater produces unwanted
odors
Heater shuts off in use (ODS
operates)
Gas odor even when control knob
is in OFF position
Gas odor during combustion
Log set cycles to pilot, but room
temperature drops to a lower than
ideal level before log set comes
back on